Chilling

Functionality That Couldn't Be More Precise...For Environments That Couldn't Be More Fragile.

Aqua Logic understands the critical role that water temperature plays in your aquatic application and we offer the widest range of chilling and heating equipment.
Designed specifically for the unique markets we serve, we've been manufacturing the most reliable and accurate equipment, using only pure titanium coils and the highest quality components, for more than 25 years.

Please specify the table IDPlease specify the table IDPlease specify the table IDPlease specify the table IDPlease specify the table ID
ChillersHeat ExchangersCold Water Building Loop Systems

Chillers

Time to Chill. In less time than ever.

When it comes to water chillers, one size does not fit all. Aqua Logic manufactures chillers specifically designed for a wide variety of applications, so that they always meet your expectations. Installed in major public aquariums, the largest marine research labs in the world, and industries where corrosive fluids need to be cooled, Aqua Logic’s oversized helical titanium coil maximizes Btu transfer efficiency to deliver the consistent cold temperature you require.

When there’s zero room for error...we’re 100% committed.

We understand the critical role your equipment plays in your research or keeping marine life alive, which is why we’ve set the standard for the water chiller industry. From the environmentally stable insulation on the evaporator, to shut down safety flow switches and current/phase monitoring electronics, we’ve got you covered so that you can focus on your operation.

100% Titanium. 100% Satisfaction.

We use the most stable materials so you get the most accurate results.  Aqua Logic Chillers are built strong to last long.

 

[accordion openfirst='false' clicktoclose='true'][accordion-item title='Delta Star® In-line Water Chillers']
DeltaStar-In-lineWaterChillers

Delta Star® In-line Water Chillers

Delta Star® In-line Water Chillers

Categories: ,

Compact in-line units for smaller applications. Chills 50-2000 gallons to between 5 and 40ºF below ambient air temperature.

  • Delta Star® Air-Cooled Chillers
  • Delta Star® Water-Cooled Chillers
  • Delta Star® Water-Cooled Marine Duty Chiller
[/accordion-item][accordion-item title='Delta Star® Air-Cooled Chillers']
Delta Star Chiller
DS in shopRegular camera as of Feb 2 672 – CopyDelta Star in boxDelta Stars ProductionDS-9Delta Star Air Cooled ChillerRegular camera as of Feb 2 688

Delta Star® Air-Cooled Chillers

Delta Star® Air-Cooled Chillers

$0.00$1,350.00

Clear selection
SKU: N/A Categories: ,

¼ Hp – 1 ½ Hp

  • Maintains water temperatures in the range of 40° – 80°F (*see specifications)
  • Oversized helical titanium coil in the heat exchanger maximizes BTU transfer efficiency.
  • TITANIUM is the only heat exchanger material proven to be 100% fish and coral safe in saltwater systems.
  • Quiet, internal, spring mounted hermetic motor/compressor provides years of reliable service.
  • Low profile and compact design allows for easy placement in tight places.

Applications:

  • Living Exhibits
  • Research
  • Lobster and Seafood Holding tanks
  • Hydroponics
  • Home Aquariums
  • Cold plunge tubs
  • Animal hydrotherapy

System Requirements:

  • An external pump is required with Delta Star chillers to move water thru the heat exchanger. Pump not included.
  • Observe min/max flow rates critical to chiller operation in ‘Specifications’ table
  • Chiller must not be placed in a confined space, as restricted air flow will limit the efficiency and lifespan of the chiller unit. Do not restrict airflow by placing unit in a cabinet or closet.
  • A Cold Water Cap Tube (CWCT) is required for desired water temps between 50-65F on available models. Standard units operate in the range of 65-85 F.  Call to order.
  • A Thermal Expansion Valve (TXV) is required for lower desired water temps between 40-80F on available models. Standard units operate in the range of 65-85 F. Call to order.
    • Features
    • Sizing
    • Specifications
    • Product Literature
    • Product Inquiry
    • In-Line Tube In Shell Heat Exchanger
    • Titanium coil
    • Digital Temperature Controller
    • Fresh or Saltwater Use
    • Compact Design
    • FIPT connections In/Out
    • Quiet Operation
    • Black ABS Cover
    • Remote Electronic Temperature Controller
    • Ozone Friendly Refrigerant (134A)

    The following tables can be used to determine the appropriate Delta Star Chiller Model chiller for your application.

    Tables display the maximum water volume (Gallons) that can be maintained at a range of temperature differences below the ambient air temperature. Please note that the tables make the following assumptions, and that for more accurate sizing or complex systems you should contact Aqua Logic for assistance:

    • Calculations based on a closed recirculating system with chiller running full time.
    • Calculations based on a simple system with one pump, 3x per hour water turnover rate, and fluorescent lighting.
    • Please consult Aqua Logic for proper sizing if using multiple pumps, protein skimmers, high intensity lighting, or other such variables.

    Sizing Table 1-Uninsulated Tanks: Acrylic and Glass. Note: For Polypropylene/ethylene multiply gallons x 0.8= net gallons.

    Temperature "chill down" from ambient (oF) per tank volume (US Gallons)

    Model No. Hp Nominal BTU/hr 5 oF 10 oF 15 oF 20 oF 25 oF 30 oF 35 oF 40 oF
    DS-3 1/4 3080 592 296 197 148 118 99 85 74
    DS-4 1/3 4050 778 389 259 194 156 130 111 97
    DS-5 & DS-6 1/2 6000 1152 576 384 288 230 192 165 144
    DS-7 & DS-8 3/4 9500 1825 912 608 456 365 304 261 228
    DS-9 1 12000 3457 1729 1152 864 691 576 494 432
    DS-10 1 1/2 18000 5186 2593 1729 1297 1037 864 741 648
    Enlarge

    Sizing Table 2- Insulated Tanks.

    Temperature "chill down" from ambient (oF) per tank volume (US Gallons)

    Model No. Hp Nominal BTU/hr 5 oF 10 oF 15 oF 20 oF 25 oF 30 oF 35 oF 40 oF
    DS-3 1/4 3080 887 444 296 222 177 148 127 111
    DS-4 1/3 4050 1167 583 389 292 233 194 167 146
    DS-5 & DS-6 1/2 6000 1729 864 576 432 346 288 247 216
    DS-7 & DS-8 3/4 9500 2737 1369 912 684 547 456 391 342
    DS-9 1 12000 4610 2305 1537 1152 922 768 659 576
    DS-10 1 1/2 18000 6915 3457 2305 1729 1383 1152 988 864
    Enlarge

    To ensure accurate sizing of your Delta Star chiller please provide us with details about your specific application via the ‘Request a Quote' tab.

     

     

    Model Number Horse Power BTUH Removal Capacity Volts/Phase Amps Flow (gpm) Min/Max In/Out FIPT (in) Length (in) Width (in) Height (in) Shipping Weight (lbs)
    DS-3 1/4 3,000 115 5.4 8/15 3/4" 22 1/2" 13 1/2" 11 1/4" 62 lbs.
    DS-4 1/3 4,000 115 7.2 10/20 3/4" 22 1/2" 13 1/2" 11 1/4" 62 lbs.
    DS-5 1/2 6,000 115 9.5 12/25 1-1/2" 24" 15 1/4" 13 1/8" 110 lbs.
    DS-6 1/2 6,000 230 4.8 12/25 1-1/2" 24" 15 1/4" 13 1/8" 112 lbs.
    DS-7 3/4 9,500 115 15.4 15/30 1-1/2" 25" 24 14 3/4" 145 lbs.
    DS-8 3/4 9,500 230 8.4 15/30 1-1/2" 25" 24" 14 3/4" 145 lbs.
    DS-9 1 12,000 230 9 20/35 1-1/2" 26 1/2" 28" 17 3/4" 150 lbs.
    DS-10 1 1/2 21,000 230 10.5 25/40 1-1/2" 26 1/4" 26" 17 1/2" 190 lbs.
    Enlarge

     

    *Add “CWCT” (cold water cap tube) to model # for desired water temps between 50-65F on available models.
    *Add “TXV” to model # for lower desired water temps between 40-80F on available models.

    Standard

    • Ideal for tropical aquariums and warm water exhibits, or research applications.
    • Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
    • Amount of refrigerant does not need to change since the water temperature is being maintained at a constant.

    ‘CWCT’ (Cold Water Cap Tube)

    • Allows for a lower, but more limited temperature range.
    • Ideal for bait fish holding, temperate fish exhibits, and hydroponics.
    • Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
    • Amount of refrigerant does not need to change since the water temperature is being maintained at a constant.

    “TXV” (Thermal Expansion Valve)

    • Provides both the lowest water temperature and the most broad temperature range.
    • Required for applications where the unit will need to maintain a very cold temperature.
    • Ideal for lobster tanks, cold water fish exhibits, or research applications.
    • The thermal expansion valve constantly regulates the amount of refrigerant going to the heat exchanger based on the desired water temperature.

    We will be happy to assist you in choosing the correct chiller for your application. Please Request a Quote and provide us with your information.

     

    Interested in this product line? Just fill out the form below and we'll get in touch shortly with answers to your questions and solutions for your problems.






      [/accordion-item][accordion-item title='Cyclone® Drop-In Chillers']
      cyclone-drop-in-coil-chiller

      Cyclone® Drop-In Chillers

      Cyclone® Drop-In Chillers

      $0.00$1,477.00

      Clear selection
      SKU: N/A Categories: ,

      1/4- ½ Hp

      • No plumbing required; drop titanium coil directly in tank or sump
      • Maintains water temperatures in the range of 50° – 80°F (*see specifications)
      • Oversized helical titanium coil in the heat exchanger maximizes BTU transfer efficiency.
      • TITANIUM is the only heat exchanger material proven to be 100% fish and coral safe in saltwater systems.
      • Quiet, internal, spring mounted hermetic motor/compressor provides years of reliable service.
      • Low profile and compact design allows for easy placement in tight places.

      Applications:

      • Living Exhibits
      • Research
      • Lobster and Seafood Holding tanks
      • Hydroponics
      • Home Aquariums
      • Cold plunge tubs
      • Animal hydrotherapy

      System Requirements:

      • Cyclone drop in chillers require that the coil always be completely immersed in water with adequate water flow.
      • Observe min/max flow rates critical to chiller operation in ‘Specifications’ table
      • Chiller unit must not be placed in a confined space, as restricted air flow will limit the efficiency and lifespan. Do not restrict airflow by placing unit in a cabinet or closet.
      • A Cold Water Cap Tube (CWCT) is required for desired water temps between 50-65F on available models. Standard units operate in the range of 65-85 F. Call to order.
        • Features
        • Sizing
        • Specifications
        • Options
        • Product Literature
        • Product Inquiry
        • Air-Cooled
        • No Plumbing Required
        • Fresh or Saltwater Use
        • 5 ft Flexible Refrigeration Line
        • Compact Design
        • Quiet Operation
        • Black ABS Cover
        • Remote Electronic Temperature Controller
        • Ozone Friendly Refrigerant (134A)

        Use the tables below to determine the appropriate Cyclone Chiller model for your application.

        Please note that the tables make the following assumptions;

        • Calculations based on a closed recirculating system with chiller running full time.
        • Calculations based on a simple system with one pump, 3x per hour water turnover rate, and fluorescent lighting.
        • Do not take into account, multiple pumps, protein skimmers, high intensity lighting, or other such variables.

         

        Sizing Table 1-Uninsulated Tanks: Acrylic and Glass.
        Note: For Polypropylene/ethylene multiply gallons x 0.8= net gallons.

        Temperature "chill down" from ambient (oF) per tank volume (US Gallons)

        Model No. Hp Nominal BTU/hr 5 oF 10 oF 15 oF 20 oF 25 oF 30 oF 35 oF 40 oF
        CY-3 1/4 3080 592 296 197 148 118 99 85 74
        CY-4 1/3 4050 778 389 259 194 156 130 111 97
        CY-5 & CY-6 1/2 6000 1152 576 384 288 230 192 165 144
        Enlarge

         

         

        Sizing Table 2- Insulated Tanks

        Temperature "chill down" from ambient (oF) per tank volume (US Gallons)

        Model No. Hp Nominal BTU/hr 5 oF 10 oF 15 oF 20 oF 25 oF 30 oF 35 oF 40 oF
        CY-3 1/4 3080 887 444 296 222 177 148 127 111
        CY-4 1/3 4050 1167 583 389 292 233 194 167 146
        CY-5 & CY-6 1/2 6000 1729 864 576 432 346 288 247 216
        Enlarge

         

         

        We recommend using our help to accurately determine the Cyclone Drop-In chiller size that will work for you. Please contact us for assistance or  provide us with the details of your application via the ‘Request a Quote’ tab.

        Model No. HP Nominal BTUH R134A Refrigerant Charge (oz.) Volts/Phase Amps. Watts Water Flow Rate (GPM) Air Output (CFM) L W H Coil Length Coil Height Shipping Weight (lbs.) Shipping Dimensions (in.)
        CY-3 1/4 3,000 5 115 5.4 621 8-15 240 17 1/2" 13 1/2" 11 1/4" 7 1/4" 2 1/8" 53 26 x 16 x 15
        CY-4 1/3 4,000 8 115 7.2 828 10-20 260 17 1/2" 13 1/2" 11 1/4" 9" 2 1/8" 62 26 x 16 x 15
        CY-5 1/2 6,000 9.5 115 9.5 1092 12-25 350 17 1/2" 15 1/4" 13 1/8" 9 1/8" 3" 110 33 x 26 x 24
        CY-6 1/2 6,000 9.5 230 / 1 4.8 1104 12-25 350 17 1/2" 15 1/4" 13 1/8" 9 1/8" 3" 112 33 x 26 x 24
        Enlarge

        *Add “CWCT” (cold water cap tube) to model # for desired water temps between 50-65F on available models.

        Standard

        • Ideal for tropical aquariums and warm water exhibits, or research applications.
        • Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
        • Amount of refrigerant does not need to change since the water temperature is being maintained at a constant.

        ‘CWCT’ (Cold Water Cap Tube)

        • Allows for a lower, but more limited temperature range.
        • Ideal for bait fish holding, temperate fish exhibits, and hydroponics.
        • Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
        • Amount of refrigerant does not need to change since the water temperature is being maintained at a constant.
        Option Desired Water Temperature (ºF) Desired Water Temperature (ºC) CY-3 CY-4 CY-5 CY-6
        Standard 65-80 °F 18-27ºC
        CWCT 50-65ºF 10-18ºC
        Enlarge

        Standard

        • Ideal for tropical aquariums and warm water exhibits, or research applications.
        • Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
        • Amount of refrigerant does not need to change since the water temperature is being maintained at a constant.

        ‘CWCT’ (Cold Water Cap Tube)

        • Allows for a lower, but more limited temperature range.
        • Ideal for bait fish holding, temperate fish exhibits, and hydroponics.
        • Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
        • Amount of refrigerant does not need to change since the water temperature is being maintained at a constant.

        Interested in this product line? Just fill out the form below and we'll get in touch shortly with answers to your questions and solutions for your problems.






          [/accordion-item][accordion-item title='Multi-Temp Chillers']
          MTC

          Multi-Temp Chillers

          Multi-Temp Chillers

          Categories: ,

          Commercial Duty Chillers for any size or application.

          • Multi Temp Water-Cooled Chiller
          • Multi Temp Air-Cooled Chiller
          • Multi Temp Water-Cooled Marine Duty Chiller
          [/accordion-item][/accordion]

          Heat Exchangers

          Titanium Strong to Last Long

          Aqua Logic is the leader in Heat Exchanger design and performance, with more than 25 years manufacturing the finest quality, high-grade titanium units. With the widest range of heat exchangers available, and limitless capabilities to build custom sizes and styles, there is no heat transfer requirement we can’t meet. Our customers look no further for dependable performance that is easy to install and maintain, is food, plant, and animal safe, and built to last.

          Our commitment to continual product design and development means that we grow with our customer markets to provide solutions as new challenges arise, and because we manufacture everything right here in our San Diego facility we can modify any of our existing designs to fit your space and need.

          Available with helical coils, tube sheets, and flat plates, our superior titanium construction makes Aqua Logic Heat Exchangers non-corrosive and safe for use in both fresh and saltwater. They can easily be connected to an existing hot or cold water loop, or run with refrigerant.

          [accordion openfirst='false' clicktoclose='true'][accordion-item title='Direct Expansion Heat Exchanger Packs']
          HX36-DX
          HX36-DX-1HX36-DX-2HX36-DX-3

          Direct Expansion Heat Exchanger Packs

          Direct Expansion Heat Exchanger Packs

          Categories: ,

          Aqua Logic DX (Direct Expansion) Heat Exchanger Packs offer the ability to build a chiller or heat pump in the field by essentially making your own “split system”. Install the compact DX Heat Exchanger Pack near the plumbing it needs to be connected to, for easy access to the temperature controller and refrigeration components. Each complete DX Heat Exchanger Pack comes neatly mounted on a tidy stainless steel frame and comes pre-plumbed and wired for quick and easy installation.

          The chiller condensing unit can be located at a distance, either outside or in an equipment room, and the two components are connected via insulated copper refrigeration lines by an on-site refrigeration contractor.

          This flexibility makes this a great option for tight spaces and keeps your LSS or work area free and clear of clunky condensing units and messy refrigeration lines. Purchase a condensing unit from Aqua Logic, or use one that you already have on-site, to quickly and economically build a chiller or heat pump for a broad range of aquatic applications.

          Made to order. Not available for sale in online store. Please contact us for assistance with sizing and purchase.

            • Features
            • Sizing
            • Specifications
            • Product Literature
            • Product Inquiry
            • 1/5 Hp (1,800 BTUs) and larger
            • For “Split System” Chiller and Heat Pump applications
            • Complete package; Pre-plumbed and wired for quick, easy installation
            • Compact Design
            • Frame mounted on stainless steel frame
            • Titanium helical coil or tube sheet heat exchanger (size dependent)
            • Insulated PVC chiller barrel
            • Expansion valve
            • Sight glass
            • Digital Temperature Controller
            • Solenoid valve
            • Flow Switch
            • Custom piping
            • Pre-plumbed and wired for installation

            This pre-wired and pre-engineered system make both ordering and assembly simple. All you need is a condensing unit of your choice or one supplied by Aqua Logic.

             System Requirements:

            • Observe min and max flow rates specific to your set temperature
            • An external pump is required to move water through the heat exchanger.
            • Bypass or isolation valves should be installed for servicing heat exchanger while system is running

            A number of factors influence the correct size of heat exchanger required for your application. While standard Btu calculations can be applied, and our specifications can offer some guidelines, the parameters of your application will be the deciding factor in correct size selection.

            Contact us today for help with sizing the perfect unit for your needs.

            For use as a water chiller: ‘HX-DX’ models

            *Minimum flow rate at 65F and above. At 65F and below 120GPM minimum flow rate.
            ** Units 10Hp and larger will have a dual circuit on a manifold if ordering from the specification tables above. For dual circuit and two points of connection order ‘DXD’ models from specification table below.

            For use as a heat pump: ‘HX-DX-HP’ models

            Dual Circuit for use as water chiller: ‘HX-DXD’ models include a dual circuit.
            Optional on units 10 Hp and larger.

            *Minimum flow rate at 65F and above.  At 65F and below 120GPM minimum flow rate.

            Interested in this product line? Just fill out the form below and we'll get in touch shortly with answers to your questions and solutions for your problems.






              [/accordion-item][accordion-item title='Water to Water Heat Exchanger Packs']
              HX-240-W
              HX-W-WaterToWater-ex1HX-W-WaterToWater-ex2HX-W-WaterToWater-ex3

              Water to Water Heat Exchanger Packs

              Water to Water Heat Exchanger Packs

              Categories: ,

              When you have a water-to-water heat exchange challenge, Aqua Logic has the solution. Our compact Water-to-Water Heat Exchanger Packs offer the ability to build a chiller in the field by simply connecting the unit to the system plumbing and to an existing water supply. Each complete pack comes pre-plumbed and pre-wired for quick and easy installation. Mounted on a tidy stainless steel rack, the pack can be hung anywhere for convenient access to temperature controls.

              With unbeatable performance and our trademark quality titanium construction, our water-to- water heat exchanger packs are the best choice for your closed hot or cold water loop system.

              Made to order. Not available for sale in online store. Please contact us for assistance with sizing and purchase.

                • Features
                • Sizing
                • Product Literature
                • Product Inquiry
                • 1/5 Hp (1,800 BTUs) and Larger
                • Complete Package
                • Titanium Tube Sheet Heat Exchanger
                • Insulated PVC Shell
                • Stainless Steel Mounting Frame
                • Digital Temperature Controller
                • 3-way Water Solenoid Valve
                • Water Flow Meter
                • Inline Strainer
                • Customized plumbing
                • Easy Installation
                • Compact Design
                • Fresh or Saltwater Use
                • Use on Hot or Chilled Loops

                System Requirements:

                • If using with a hot water loop please specify at time of order and heat exchanger barrel will be made in CPVC
                • Each pack requires a 120v electrical outlet
                • Bypass or isolation valves should be installed for servicing heat exchanger while system is running
                • Observe min and max flow rates specific to your set temperature
                • An external pump is required to move water through the heat exchanger.

                A number of factors influence the correct size of heat exchanger required for your application, including the temperature of your supply water. While standard Btu calculations can be applied, and our specifications can offer some guidelines, the parameters of your application will be the deciding factor in correct size selection.

                Contact us today for help with sizing the perfect unit for your needs.

                Interested in this product line? Just fill out the form below and we'll get in touch shortly with answers to your questions and solutions for your problems.






                  [/accordion-item][accordion-item title='Titanium Heat Exchangers (Barrel Only)']
                  HX-240-W

                  Titanium Heat Exchangers (Barrel Only)

                  Titanium Heat Exchangers (Barrel Only)

                  Read more
                  Read more
                  Categories: ,

                  Aqua Logic Heat Exchangers are renowned for their compact profiles, efficient heat transfer, compatibility, and durability. Used among a wide variety of commercial industries, from aquaculture, to grow houses, to breweries, our huge range of sizes and styles cover all bases. As a favorite amongst public aquariums and zoos, you’d be hard pressed to find an institution in the industry that doesn’t rely on our outstanding heat exchanging abilities.

                  We offer two styles of titanium Heat Exchanger barrel that are designed for maximum efficiency in both refrigerant and water to water applications.

                  • Titanium Tube-In-Shell Heat Exchanger
                  • Titanium Tube Sheet Heat Exchanger
                  [/accordion-item][accordion-item title='Plate & Frame Heat Exchangers']
                  flat plate
                  dual-plate-hexdual-plate-hex-2

                  Plate & Frame Heat Exchangers

                  Plate & Frame Heat Exchangers

                  Categories: ,

                  Aqua Logic represents many brands of Plate and Frame Heat Exchangers, available in both Titanium and Stainless Steel. We hold our product partners to our high standards in quality and integrity so that our customers can rest assured they are getting the best components across the board. We can provide you with a plate heat exchanger on its own or incorporate them into a turnkey filtration package or specialized unit as you see fit.

                  • Available in Titanium or Stainless Steel
                  • Fresh or Saltwater Use
                  • Use as Heat Exchanger or Condenser
                  • Compact Design
                  • Compatible with Refrigerant, Water or Glycol
                  • Available in a Wide Range of Configurations

                  Contact us for more information and to request a quote.

                    [/accordion-item][/accordion]

                    Cold Water Building Loop Systems

                    Where several temperature zones are required, Aqua Logic’s Cold/Hot Building Loop Systems offer the installer a complete, water-to-water, ready to use, time tested combination chiller plant and in-line heat exchangers, using quality built components and our trademark TITANIUM coils; the only material proven to be 100% fish and coral safe in saltwater systems.

                    [accordion openfirst='false' clicktoclose='true'][accordion-item title='Cold Water Building Loop System']
                    cold_hot
                    chilled-water-loop-drawingglycol-loop-drawing

                    Cold Water Building Loop System

                    Cold Water Building Loop System

                    Aqua Logic's Cold or Hot water Building Loop Systems come complete with everything needed to quickly and easily install the entire system in a matter of a few hours.

                    Our system packages provide economic and operational advantages that have made us the go-to original equipment manufacturer for commercial operations and facilities in industries like: hydroponics, aquatic and medical research, aquaculture, breweries and distilleries, seafood, athletics and rehabilitation, museums, and of course, public aquariums and zoos.

                    Overview:

                    • Complete water-to-water combination chiller plant/ heat exchanger
                    • Includes temperature control system.
                    • Custom Engineered to meet your specific requirements
                    • Maintains water temperatures within 1ºF of set point
                    • Pre-assembled and ready to install easily in a matter of hours
                    • Pre-plumbed and wired for simple connections
                    • Oversized helical titanium coil in the heat exchanger maximizes BTU transfer efficiency.
                    • Quiet, internal, spring mounted hermetic motor/compressor provides years of reliable service.
                    • Fresh or saltwater use

                    System Requirements:

                    • Existing water supply loop in building
                    • Requires external pump(s), not included but optional with purchase of pack.
                    • May require reservoir tank(s)
                    • For hot water use, specify at time of order and all PVC parts will be replaced with CPVC
                      • Features
                      • Specifications
                      • Product Inquiry

                      Each Building Loop System Includes:

                      • Pre-packaged chilled loop cold water plant
                      • Titanium and PVC heat exchangers
                      • Stainless steel mounting stands (powder coated for saltwater use)
                      • Digital Temperature Controllers
                      • Three-way water solenoid valves
                      • Water Flow meters
                      • In-line strainers
                      • FIPT connections In/Out
                      • Quiet Operation
                      • Remote Electronic Temperature Controller
                      • Ozone Friendly Refrigerant (134A)

                      Aqua Logic’s engineers will design a Building Loop System to your exact specifications. Request a quote or give us a call to discuss your requirements and we’ll customize a system to meet them.

                       

                      Interested in this product line? Just fill out the form below and we'll get in touch shortly with answers to your questions and solutions for your problems.






                        [/accordion-item][/accordion]