Chilling
Functionality That Couldn't Be More Precise...For Environments That Couldn't Be More Fragile.
Aqua Logic understands the critical role that water temperature plays in your aquatic application and we offer the widest range of chilling and heating equipment.
Designed specifically for the unique markets we serve, we've been manufacturing the most reliable and accurate equipment, using only pure titanium coils and the highest quality components, for more than 25 years.
Chillers
Time to Chill. In less time than ever.
When it comes to water chillers, one size does not fit all. Aqua Logic manufactures chillers specifically designed for a wide variety of applications, so that they always meet your expectations. Installed in major public aquariums, the largest marine research labs in the world, and industries where corrosive fluids need to be cooled, Aqua Logic’s oversized helical titanium coil maximizes Btu transfer efficiency to deliver the consistent cold temperature you require.
When there’s zero room for error...we’re 100% committed.
We understand the critical role your equipment plays in your research or keeping marine life alive, which is why we’ve set the standard for the water chiller industry. From the environmentally stable insulation on the evaporator, to shut down safety flow switches and current/phase monitoring electronics, we’ve got you covered so that you can focus on your operation.
100% Titanium. 100% Satisfaction.
We use the most stable materials so you get the most accurate results. Aqua Logic Chillers are built strong to last long.
Delta Star® In-line Water Chillers
Delta Star® In-line Water Chillers
Delta Star® In-line Water Chillers
Compact in-line units for smaller applications. Chills 50-2000 gallons to between 5 and 40ºF below ambient air temperature.
- Delta Star® Air-Cooled Chillers
- Delta Star® Water-Cooled Chillers
- Delta Star® Water-Cooled Marine Duty Chiller
Delta Star® Air-Cooled Chillers
¼ Hp – 1 ½ Hp
- Maintains water temperatures in the range of 40° – 80°F (*see specifications)
- Oversized helical titanium coil in the heat exchanger maximizes BTU transfer efficiency.
- TITANIUM is the only heat exchanger material proven to be 100% fish and coral safe in saltwater systems.
- Quiet, internal, spring mounted hermetic motor/compressor provides years of reliable service.
- Low profile and compact design allows for easy placement in tight places.
Applications:
- Living Exhibits
- Research
- Lobster and Seafood Holding tanks
- Hydroponics
- Home Aquariums
- Cold plunge tubs
- Animal hydrotherapy
System Requirements:
- An external pump is required with Delta Star chillers to move water thru the heat exchanger. Pump not included.
- Observe min/max flow rates critical to chiller operation in ‘Specifications’ table
- Chiller must not be placed in a confined space, as restricted air flow will limit the efficiency and lifespan of the chiller unit. Do not restrict airflow by placing unit in a cabinet or closet.
- A Cold Water Cap Tube (CWCT) is required for desired water temps between 50-65F on available models. Standard units operate in the range of 65-85 F. Call to order.
- A Thermal Expansion Valve (TXV) is required for lower desired water temps between 40-80F on available models. Standard units operate in the range of 65-85 F. Call to order.
- Features
- Sizing
- Specifications
- Product Literature
- Product Inquiry
- In-Line Tube In Shell Heat Exchanger
- Titanium coil
- Digital Temperature Controller
- Fresh or Saltwater Use
- Compact Design
- FIPT connections In/Out
- Quiet Operation
- Black ABS Cover
- Remote Electronic Temperature Controller
- Ozone Friendly Refrigerant (134A)
The following tables can be used to determine the appropriate Delta Star Chiller Model chiller for your application.
Tables display the maximum water volume (Gallons) that can be maintained at a range of temperature differences below the ambient air temperature. Please note that the tables make the following assumptions, and that for more accurate sizing or complex systems you should contact Aqua Logic for assistance:
- Calculations based on a closed recirculating system with chiller running full time.
- Calculations based on a simple system with one pump, 3x per hour water turnover rate, and fluorescent lighting.
- Please consult Aqua Logic for proper sizing if using multiple pumps, protein skimmers, high intensity lighting, or other such variables.
Sizing Table 1-Uninsulated Tanks: Acrylic and Glass. Note: For Polypropylene/ethylene multiply gallons x 0.8= net gallons.
Temperature "chill down" from ambient (oF) per tank volume (US Gallons)
Model No. | Hp | Nominal BTU/hr | 5 oF | 10 oF | 15 oF | 20 oF | 25 oF | 30 oF | 35 oF | 40 oF |
---|---|---|---|---|---|---|---|---|---|---|
DS-3 | 1/4 | 3080 | 592 | 296 | 197 | 148 | 118 | 99 | 85 | 74 |
DS-4 | 1/3 | 4050 | 778 | 389 | 259 | 194 | 156 | 130 | 111 | 97 |
DS-5 & DS-6 | 1/2 | 6000 | 1152 | 576 | 384 | 288 | 230 | 192 | 165 | 144 |
DS-7 & DS-8 | 3/4 | 9500 | 1825 | 912 | 608 | 456 | 365 | 304 | 261 | 228 |
DS-9 | 1 | 12000 | 3457 | 1729 | 1152 | 864 | 691 | 576 | 494 | 432 |
DS-10 | 1 1/2 | 18000 | 5186 | 2593 | 1729 | 1297 | 1037 | 864 | 741 | 648 |
Sizing Table 2- Insulated Tanks.
Temperature "chill down" from ambient (oF) per tank volume (US Gallons)
Model No. | Hp | Nominal BTU/hr | 5 oF | 10 oF | 15 oF | 20 oF | 25 oF | 30 oF | 35 oF | 40 oF |
---|---|---|---|---|---|---|---|---|---|---|
DS-3 | 1/4 | 3080 | 887 | 444 | 296 | 222 | 177 | 148 | 127 | 111 |
DS-4 | 1/3 | 4050 | 1167 | 583 | 389 | 292 | 233 | 194 | 167 | 146 |
DS-5 & DS-6 | 1/2 | 6000 | 1729 | 864 | 576 | 432 | 346 | 288 | 247 | 216 |
DS-7 & DS-8 | 3/4 | 9500 | 2737 | 1369 | 912 | 684 | 547 | 456 | 391 | 342 |
DS-9 | 1 | 12000 | 4610 | 2305 | 1537 | 1152 | 922 | 768 | 659 | 576 |
DS-10 | 1 1/2 | 18000 | 6915 | 3457 | 2305 | 1729 | 1383 | 1152 | 988 | 864 |
To ensure accurate sizing of your Delta Star chiller please provide us with details about your specific application via the ‘Request a Quote' tab.
Model Number | Horse Power | BTUH Removal Capacity | Volts/Phase | Amps | Flow (gpm) Min/Max | In/Out FIPT (in) | Length (in) | Width (in) | Height (in) | Shipping Weight (lbs) |
---|---|---|---|---|---|---|---|---|---|---|
DS-3 | 1/4 | 3,000 | 115 | 5.4 | 8/15 | 3/4" | 22 1/2" | 13 1/2" | 11 1/4" | 62 lbs. |
DS-4 | 1/3 | 4,000 | 115 | 7.2 | 10/20 | 3/4" | 22 1/2" | 13 1/2" | 11 1/4" | 62 lbs. |
DS-5 | 1/2 | 6,000 | 115 | 9.5 | 12/25 | 1-1/2" | 24" | 15 1/4" | 13 1/8" | 110 lbs. |
DS-6 | 1/2 | 6,000 | 230 | 4.8 | 12/25 | 1-1/2" | 24" | 15 1/4" | 13 1/8" | 112 lbs. |
DS-7 | 3/4 | 9,500 | 115 | 15.4 | 15/30 | 1-1/2" | 25" | 24 | 14 3/4" | 145 lbs. |
DS-8 | 3/4 | 9,500 | 230 | 8.4 | 15/30 | 1-1/2" | 25" | 24" | 14 3/4" | 145 lbs. |
DS-9 | 1 | 12,000 | 230 | 9 | 20/35 | 1-1/2" | 26 1/2" | 28" | 17 3/4" | 150 lbs. |
DS-10 | 1 1/2 | 21,000 | 230 | 10.5 | 25/40 | 1-1/2" | 26 1/4" | 26" | 17 1/2" | 190 lbs. |
*Add “CWCT” (cold water cap tube) to model # for desired water temps between 50-65F on available models.
*Add “TXV” to model # for lower desired water temps between 40-80F on available models.
Standard
- Ideal for tropical aquariums and warm water exhibits, or research applications.
- Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
- Amount of refrigerant does not need to change since the water temperature is being maintained at a constant.
‘CWCT’ (Cold Water Cap Tube)
- Allows for a lower, but more limited temperature range.
- Ideal for bait fish holding, temperate fish exhibits, and hydroponics.
- Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
- Amount of refrigerant does not need to change since the water temperature is being maintained at a constant.
“TXV” (Thermal Expansion Valve)
- Provides both the lowest water temperature and the most broad temperature range.
- Required for applications where the unit will need to maintain a very cold temperature.
- Ideal for lobster tanks, cold water fish exhibits, or research applications.
- The thermal expansion valve constantly regulates the amount of refrigerant going to the heat exchanger based on the desired water temperature.
We will be happy to assist you in choosing the correct chiller for your application. Please Request a Quote and provide us with your information.
- INSTRUCTIONS- Delta Star Air-Cooled Chillers
- SPEC SHEET- 1/4Hp Delta Star Thru 1/2Hp Delta Star Chillers
- SPEC SHEET- 3/4Hp Delta Star Thru 1 1/2Hp Delta Star Chillers
- TWO-YEAR LIMITED WARRANTY-Delta Star Air-Cooled Chillers
- WIRING DIAGRAM-1/4Hp Delta Star Thru 1/2Hp Delta Star, Split Units, 115V
- WIRING DIAGRAM-3/4Hp Delta Star Thru 1 1/2Hp Delta Star, Split Units, 220v
- SIZING WORKSHEET
Interested in this product line? Just fill out the form below and we'll get in touch shortly with answers to your questions and solutions for your problems.
Cyclone® Drop-In Chillers
1/4- ½ Hp
- No plumbing required; drop titanium coil directly in tank or sump
- Maintains water temperatures in the range of 50° – 80°F (*see specifications)
- Oversized helical titanium coil in the heat exchanger maximizes BTU transfer efficiency.
- TITANIUM is the only heat exchanger material proven to be 100% fish and coral safe in saltwater systems.
- Quiet, internal, spring mounted hermetic motor/compressor provides years of reliable service.
- Low profile and compact design allows for easy placement in tight places.
Applications:
- Living Exhibits
- Research
- Lobster and Seafood Holding tanks
- Hydroponics
- Home Aquariums
- Cold plunge tubs
- Animal hydrotherapy
System Requirements:
- Cyclone drop in chillers require that the coil always be completely immersed in water with adequate water flow.
- Observe min/max flow rates critical to chiller operation in ‘Specifications’ table
- Chiller unit must not be placed in a confined space, as restricted air flow will limit the efficiency and lifespan. Do not restrict airflow by placing unit in a cabinet or closet.
- A Cold Water Cap Tube (CWCT) is required for desired water temps between 50-65F on available models. Standard units operate in the range of 65-85 F. Call to order.
- Features
- Sizing
- Specifications
- Options
- Product Literature
- Product Inquiry
- Air-Cooled
- No Plumbing Required
- Fresh or Saltwater Use
- 5 ft Flexible Refrigeration Line
- Compact Design
- Quiet Operation
- Black ABS Cover
- Remote Electronic Temperature Controller
- Ozone Friendly Refrigerant (134A)
Use the tables below to determine the appropriate Cyclone Chiller model for your application.
Please note that the tables make the following assumptions;
- Calculations based on a closed recirculating system with chiller running full time.
- Calculations based on a simple system with one pump, 3x per hour water turnover rate, and fluorescent lighting.
- Do not take into account, multiple pumps, protein skimmers, high intensity lighting, or other such variables.
Sizing Table 1-Uninsulated Tanks: Acrylic and Glass.
Note: For Polypropylene/ethylene multiply gallons x 0.8= net gallons.
Temperature "chill down" from ambient (oF) per tank volume (US Gallons)
Model No. | Hp | Nominal BTU/hr | 5 oF | 10 oF | 15 oF | 20 oF | 25 oF | 30 oF | 35 oF | 40 oF |
---|---|---|---|---|---|---|---|---|---|---|
CY-3 | 1/4 | 3080 | 592 | 296 | 197 | 148 | 118 | 99 | 85 | 74 |
CY-4 | 1/3 | 4050 | 778 | 389 | 259 | 194 | 156 | 130 | 111 | 97 |
CY-5 & CY-6 | 1/2 | 6000 | 1152 | 576 | 384 | 288 | 230 | 192 | 165 | 144 |
Sizing Table 2- Insulated Tanks
Temperature "chill down" from ambient (oF) per tank volume (US Gallons)
Model No. | Hp | Nominal BTU/hr | 5 oF | 10 oF | 15 oF | 20 oF | 25 oF | 30 oF | 35 oF | 40 oF |
---|---|---|---|---|---|---|---|---|---|---|
CY-3 | 1/4 | 3080 | 887 | 444 | 296 | 222 | 177 | 148 | 127 | 111 |
CY-4 | 1/3 | 4050 | 1167 | 583 | 389 | 292 | 233 | 194 | 167 | 146 |
CY-5 & CY-6 | 1/2 | 6000 | 1729 | 864 | 576 | 432 | 346 | 288 | 247 | 216 |
We recommend using our help to accurately determine the Cyclone Drop-In chiller size that will work for you. Please contact us for assistance or provide us with the details of your application via the ‘Request a Quote’ tab.
Model No. | HP | Nominal BTUH | R134A Refrigerant Charge (oz.) | Volts/Phase | Amps. | Watts | Water Flow Rate (GPM) | Air Output (CFM) | L | W | H | Coil Length | Coil Height | Shipping Weight (lbs.) | Shipping Dimensions (in.) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CY-3 | 1/4 | 3,000 | 5 | 115 | 5.4 | 621 | 8-15 | 240 | 17 1/2" | 13 1/2" | 11 1/4" | 7 1/4" | 2 1/8" | 53 | 26 x 16 x 15 |
CY-4 | 1/3 | 4,000 | 8 | 115 | 7.2 | 828 | 10-20 | 260 | 17 1/2" | 13 1/2" | 11 1/4" | 9" | 2 1/8" | 62 | 26 x 16 x 15 |
CY-5 | 1/2 | 6,000 | 9.5 | 115 | 9.5 | 1092 | 12-25 | 350 | 17 1/2" | 15 1/4" | 13 1/8" | 9 1/8" | 3" | 110 | 33 x 26 x 24 |
CY-6 | 1/2 | 6,000 | 9.5 | 230 / 1 | 4.8 | 1104 | 12-25 | 350 | 17 1/2" | 15 1/4" | 13 1/8" | 9 1/8" | 3" | 112 | 33 x 26 x 24 |
*Add “CWCT” (cold water cap tube) to model # for desired water temps between 50-65F on available models.
Standard
- Ideal for tropical aquariums and warm water exhibits, or research applications.
- Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
- Amount of refrigerant does not need to change since the water temperature is being maintained at a constant.
‘CWCT’ (Cold Water Cap Tube)
- Allows for a lower, but more limited temperature range.
- Ideal for bait fish holding, temperate fish exhibits, and hydroponics.
- Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
- Amount of refrigerant does not need to change since the water temperature is being maintained at a constant.
Option | Desired Water Temperature (ºF) | Desired Water Temperature (ºC) | CY-3 | CY-4 | CY-5 | CY-6 |
---|---|---|---|---|---|---|
Standard | 65-80 °F | 18-27ºC | ||||
CWCT | 50-65ºF | 10-18ºC |
Standard
- Ideal for tropical aquariums and warm water exhibits, or research applications.
- Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
- Amount of refrigerant does not need to change since the water temperature is being maintained at a constant.
‘CWCT’ (Cold Water Cap Tube)
- Allows for a lower, but more limited temperature range.
- Ideal for bait fish holding, temperate fish exhibits, and hydroponics.
- Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
- Amount of refrigerant does not need to change since the water temperature is being maintained at a constant.
Interested in this product line? Just fill out the form below and we'll get in touch shortly with answers to your questions and solutions for your problems.
Multi-Temp Chillers
- Multi Temp Water-Cooled Chiller
- Multi Temp Air-Cooled Chiller
- Multi Temp Water-Cooled Marine Duty Chiller
Heat Exchangers
Titanium Strong to Last Long
Aqua Logic is the leader in Heat Exchanger design and performance, with more than 25 years manufacturing the finest quality, high-grade titanium units. With the widest range of heat exchangers available, and limitless capabilities to build custom sizes and styles, there is no heat transfer requirement we can’t meet. Our customers look no further for dependable performance that is easy to install and maintain, is food, plant, and animal safe, and built to last.
Our commitment to continual product design and development means that we grow with our customer markets to provide solutions as new challenges arise, and because we manufacture everything right here in our San Diego facility we can modify any of our existing designs to fit your space and need.
Available with helical coils, tube sheets, and flat plates, our superior titanium construction makes Aqua Logic Heat Exchangers non-corrosive and safe for use in both fresh and saltwater. They can easily be connected to an existing hot or cold water loop, or run with refrigerant.
Direct Expansion Heat Exchanger Packs
Direct Expansion Heat Exchanger Packs
Direct Expansion Heat Exchanger Packs
Aqua Logic DX (Direct Expansion) Heat Exchanger Packs offer the ability to build a chiller or heat pump in the field by essentially making your own “split system”. Install the compact DX Heat Exchanger Pack near the plumbing it needs to be connected to, for easy access to the temperature controller and refrigeration components. Each complete DX Heat Exchanger Pack comes neatly mounted on a tidy stainless steel frame and comes pre-plumbed and wired for quick and easy installation.
The chiller condensing unit can be located at a distance, either outside or in an equipment room, and the two components are connected via insulated copper refrigeration lines by an on-site refrigeration contractor.
This flexibility makes this a great option for tight spaces and keeps your LSS or work area free and clear of clunky condensing units and messy refrigeration lines. Purchase a condensing unit from Aqua Logic, or use one that you already have on-site, to quickly and economically build a chiller or heat pump for a broad range of aquatic applications.
Made to order. Not available for sale in online store. Please contact us for assistance with sizing and purchase.
- Features
- Sizing
- Specifications
- Product Literature
- Product Inquiry
- 1/5 Hp (1,800 BTUs) and larger
- For “Split System” Chiller and Heat Pump applications
- Complete package; Pre-plumbed and wired for quick, easy installation
- Compact Design
- Frame mounted on stainless steel frame
- Titanium helical coil or tube sheet heat exchanger (size dependent)
- Insulated PVC chiller barrel
- Expansion valve
- Sight glass
- Digital Temperature Controller
- Solenoid valve
- Flow Switch
- Custom piping
- Pre-plumbed and wired for installation
This pre-wired and pre-engineered system make both ordering and assembly simple. All you need is a condensing unit of your choice or one supplied by Aqua Logic.
System Requirements:
- Observe min and max flow rates specific to your set temperature
- An external pump is required to move water through the heat exchanger.
- Bypass or isolation valves should be installed for servicing heat exchanger while system is running
A number of factors influence the correct size of heat exchanger required for your application. While standard Btu calculations can be applied, and our specifications can offer some guidelines, the parameters of your application will be the deciding factor in correct size selection.
Contact us today for help with sizing the perfect unit for your needs.
For use as a water chiller: ‘HX-DX’ models
*Minimum flow rate at 65F and above. At 65F and below 120GPM minimum flow rate.
** Units 10Hp and larger will have a dual circuit on a manifold if ordering from the specification tables above. For dual circuit and two points of connection order ‘DXD’ models from specification table below.
For use as a heat pump: ‘HX-DX-HP’ models
Dual Circuit for use as water chiller: ‘HX-DXD’ models include a dual circuit.
Optional on units 10 Hp and larger.
*Minimum flow rate at 65F and above. At 65F and below 120GPM minimum flow rate.
- SPEC SHEET- 1/4Hp Thru 1Hp Direct Expansion HEX (HX-3-DX to HX-12-DX)
- SPEC SHEET- 1/2Hp Thru 5Hp Direct Expansion HEX (HX-24-DX to HX-60-DX)
- SPEC SHEET- 1/2Hp Thru 5Hp Direct Expansion HEX (HX-24-DXV to HX-60-DXV)
- SPEC SHEET- 7.5Hp Direct Expansion HEX (HX-65-DX)
- SPEC SHEET- 7.5Hp Thru 20Hp Direct Expansion HEX (HX-90-DX to HX-240-DX)
- SPEC SHEET- 2Hp Thru 5Hp Direct Expansion HEX for HEAT PUMP (HX-24-DXHP to HX-60-DXHP)
- SPEC SHEET- 10Hp Thru 20Hp Direct Expansion HEX for HEAT PUMP (HX-120-DXHP to HX-240-DXHP)
- INSTRUCTIONS- Direct Expansion HEX & Direct Expansion HEX for Heat Pump
- SIZING WORKSHEET
- SIZING WORKSHEET for Heat Exchangers
Interested in this product line? Just fill out the form below and we'll get in touch shortly with answers to your questions and solutions for your problems.
Water to Water Heat Exchanger Packs
Water to Water Heat Exchanger Packs
Water to Water Heat Exchanger Packs
When you have a water-to-water heat exchange challenge, Aqua Logic has the solution. Our compact Water-to-Water Heat Exchanger Packs offer the ability to build a chiller in the field by simply connecting the unit to the system plumbing and to an existing water supply. Each complete pack comes pre-plumbed and pre-wired for quick and easy installation. Mounted on a tidy stainless steel rack, the pack can be hung anywhere for convenient access to temperature controls.
With unbeatable performance and our trademark quality titanium construction, our water-to- water heat exchanger packs are the best choice for your closed hot or cold water loop system.
Made to order. Not available for sale in online store. Please contact us for assistance with sizing and purchase.
- Features
- Sizing
- Product Literature
- Product Inquiry
- 1/5 Hp (1,800 BTUs) and Larger
- Complete Package
- Titanium Tube Sheet Heat Exchanger
- Insulated PVC Shell
- Stainless Steel Mounting Frame
- Digital Temperature Controller
- 3-way Water Solenoid Valve
- Water Flow Meter
- Inline Strainer
- Customized plumbing
- Easy Installation
- Compact Design
- Fresh or Saltwater Use
- Use on Hot or Chilled Loops
System Requirements:
- If using with a hot water loop please specify at time of order and heat exchanger barrel will be made in CPVC
- Each pack requires a 120v electrical outlet
- Bypass or isolation valves should be installed for servicing heat exchanger while system is running
- Observe min and max flow rates specific to your set temperature
- An external pump is required to move water through the heat exchanger.
A number of factors influence the correct size of heat exchanger required for your application, including the temperature of your supply water. While standard Btu calculations can be applied, and our specifications can offer some guidelines, the parameters of your application will be the deciding factor in correct size selection.
Contact us today for help with sizing the perfect unit for your needs.
- SPEC SHEET- 3,000-12,000 BTUH HEAT EXCHANGER (HX-3-W to HX-12-W)
- SPEC SHEET- 24,000-60,000 BTUH HEAT EXCHANGER (HX-24-W to HX-60-W)
- SPEC SHEET- 24,000-60,000 BTUH VERTICAL HEAT EXCHANGER (HX-24-WV to HX-60-WV)
- SPEC SHEET- 90,000-240,000 BTUH HEAT EXCHANGER (HX-90-W to HX-240-W)
- INSTRUCTIONS- Water-to-Water Heat Exchangers
- SIZING WORKSHEET
- SIZING WORKSHEET for Heat Exchangers
Interested in this product line? Just fill out the form below and we'll get in touch shortly with answers to your questions and solutions for your problems.
Titanium Heat Exchangers (Barrel Only)
Titanium Heat Exchangers (Barrel Only)
Titanium Heat Exchangers (Barrel Only)
Aqua Logic Heat Exchangers are renowned for their compact profiles, efficient heat transfer, compatibility, and durability. Used among a wide variety of commercial industries, from aquaculture, to grow houses, to breweries, our huge range of sizes and styles cover all bases. As a favorite amongst public aquariums and zoos, you’d be hard pressed to find an institution in the industry that doesn’t rely on our outstanding heat exchanging abilities.
We offer two styles of titanium Heat Exchanger barrel that are designed for maximum efficiency in both refrigerant and water to water applications.
- Titanium Tube-In-Shell Heat Exchanger
- Titanium Tube Sheet Heat Exchanger
Plate & Frame Heat Exchangers
Plate & Frame Heat Exchangers
Plate & Frame Heat Exchangers
Aqua Logic represents many brands of Plate and Frame Heat Exchangers, available in both Titanium and Stainless Steel. We hold our product partners to our high standards in quality and integrity so that our customers can rest assured they are getting the best components across the board. We can provide you with a plate heat exchanger on its own or incorporate them into a turnkey filtration package or specialized unit as you see fit.
- Available in Titanium or Stainless Steel
- Fresh or Saltwater Use
- Use as Heat Exchanger or Condenser
- Compact Design
- Compatible with Refrigerant, Water or Glycol
- Available in a Wide Range of Configurations
Contact us for more information and to request a quote.
Cold Water Building Loop Systems
Where several temperature zones are required, Aqua Logic’s Cold/Hot Building Loop Systems offer the installer a complete, water-to-water, ready to use, time tested combination chiller plant and in-line heat exchangers, using quality built components and our trademark TITANIUM coils; the only material proven to be 100% fish and coral safe in saltwater systems.
Cold Water Building Loop System
Cold Water Building Loop System
Cold Water Building Loop System
Aqua Logic's Cold or Hot water Building Loop Systems come complete with everything needed to quickly and easily install the entire system in a matter of a few hours.
Our system packages provide economic and operational advantages that have made us the go-to original equipment manufacturer for commercial operations and facilities in industries like: hydroponics, aquatic and medical research, aquaculture, breweries and distilleries, seafood, athletics and rehabilitation, museums, and of course, public aquariums and zoos.
Overview:
- Complete water-to-water combination chiller plant/ heat exchanger
- Includes temperature control system.
- Custom Engineered to meet your specific requirements
- Maintains water temperatures within 1ºF of set point
- Pre-assembled and ready to install easily in a matter of hours
- Pre-plumbed and wired for simple connections
- Oversized helical titanium coil in the heat exchanger maximizes BTU transfer efficiency.
- Quiet, internal, spring mounted hermetic motor/compressor provides years of reliable service.
- Fresh or saltwater use
System Requirements:
- Existing water supply loop in building
- Requires external pump(s), not included but optional with purchase of pack.
- May require reservoir tank(s)
- For hot water use, specify at time of order and all PVC parts will be replaced with CPVC
- Features
- Specifications
- Product Inquiry
Each Building Loop System Includes:
- Pre-packaged chilled loop cold water plant
- Titanium and PVC heat exchangers
- Stainless steel mounting stands (powder coated for saltwater use)
- Digital Temperature Controllers
- Three-way water solenoid valves
- Water Flow meters
- In-line strainers
- FIPT connections In/Out
- Quiet Operation
- Remote Electronic Temperature Controller
- Ozone Friendly Refrigerant (134A)
Aqua Logic’s engineers will design a Building Loop System to your exact specifications. Request a quote or give us a call to discuss your requirements and we’ll customize a system to meet them.
Interested in this product line? Just fill out the form below and we'll get in touch shortly with answers to your questions and solutions for your problems.