Description
7,000 BTU/H of cooling in a cabinet barely bigger than a milk crate. Drop the titanium coil into the tank, plug the unit into a standard GFCI-protected 115V outlet, and hold your setpoint — no plumbing to cut, no compromise on corrosion resistance, just colder water!
Specification | CY-Plus |
Model no. | CYP007 |
Nominal capacity | 1/2 HP+ / 7,000 BTU/H / 2.05 kW |
Compressor | 1/2 HP rotary |
Refrigerant | R-454B (A2L), 10 oz charge |
Electrical | 115V / 1 Ph / 60 Hz |
Compressor amps | 5.9 RLA / 35 LRA |
Fan amps | 0.5 FLA |
Power cord | 6 ft, NEMA 5-15P plug |
Air output | 380 CFM |
Condenser | Aluminum microchannel (MCHE) |
Heat exchanger | Titanium drop-in coil, flexible hose |
Coil size | 9 1/8" L × 3 1/2" H |
Hose length | 72 in (6 ft) |
Water flow across coil | Ensure minimum flow across the coil |
Water level over coil | 6" min. / 8" max. |
Control | Digital with voltage protection, fan-failure alarm, and dirty-condenser alarm |
Cabinet cover | 304 stainless steel |
Cabinet dimensions | 14 3/4" W × 18 1/4" D × 14 1/2" H |
Shipping dimensions | 30 1/2" × 18 1/2" × 18 1/2" |
Ambient air temperature | 45°F – 110°F |
Weight | 57 lbs. |
Installation & Clearances
• Allow 12″ minimum clearance at both air-outlet sides and 6″ minimum at the remaining sides. Do not restrict the air intake.
• Set the coil so water is at least 6″ and no more than 8″ over it.
• For optimal temperature control, maintain 15–25 GPM of flow across the coil. Existing tank circulation is usually enough.
• Never bend the hose tighter than a 6-inch radius.
• Do not submerge the hose in water beyond the titanium riser.
• Operate between 45 °F and 110°F ambient air temperature.
• Dedicated GFCI – protected 115V circuit recommended; the integrated control monitors voltage and shuts down on an out-of-range
supply.