Super Nova UV Sterilizers | |||||||||||
Model No. | Lamp/Watts | Volts/phase | Amps/watts | Chamber Diameter | Water inlet/Outlet | Maximum Water Flow Rate (GPM) at UV Intensity µWsec/cm2 @90% transmissibility 85% at end of lamp life | |||||
30k | 45k | 60k | 90k | 120k | |||||||
ALS-7608.12 | 8/760 | 115 | 6/690 | 12″ | 6″ flange | 408 | 271 | 204 | 135 | 102 | |
ALS-95010.12 | 10/950 | 115 | 7.5/863 | 12″ | 6″ flange | 500 | 333 | 250 | 166 | 125 | |
ALS-114012.12 | 12/1140 | 115 | 9/1035 | 12″ | 6″ flange | 560 | 372 | 280 | 187 | 140 | |
ALS-114012.16 | 12/1140 | 115 | 9.1035 | 16″ | 6″ flange | 693 | 460 | 346 | 231 | 173 | |
ALS-133014.16 | 14/1330 | 220 | 10.5/1150 | 16″ | 8″ flange | 780 | 519 | 390 | 260 | 195 | |
ALS-152016.16 | 16/1520 | 220 | 12/1380 | 16″ | 8″ flange | 876 | 583 | 438 | 292 | 219 | |
Note:
A maximum water flow rate (gpm) at uv intensity – μwsec/cm2 @90% (transmissiblity 85% at end of lamp life)
B water velocities greater than 5ft / sec.
* all dimensions are approximate and can change at any time.
* water connections may change according to flow rate. Other sizes available.
Corona UV Sterilizers | ||||||||||
Model No. | Model No. Horizonal | Lamp/Watts | Volts/phase | Amps/watts | Water inlet/Outlet | Maximum Water Flow Rate (GPM) at UV Intensity µWsec/cm2 @90% transmissibility 85% at end of lamp life | ||||
30k | 45k | 60k | 90k | 120k | ||||||
ALSV-2 | ALSH-2DX | 2/190 | 115 | 1.8/207 | 2″ FPT | 50 | 33 | 25 | 16 | 13 |
ALSV-3 | ALSH-3DX | 3/285 | 115 | 2.5/287 | 3″ Union | 75 | 50 | 37 | 25 | 18 |
ALSV-4 | ALSH-4DX | 4/380 | 115 | 3/345 | 3″ Union | 100 | 67 | 50 | 37 | 25 |
ALSV-5 | ALSH-5DX | 5/475 | 115 | 4.5/517 | 4″ Union | 150 | 100 | 75 | 50 | 33 |
ALSV-6 | ALSH-6DX | 6/570 | 115 | 5.4/621 | 6″ Union | 200 | 133 | 100 | 75 | 50 |
ALSV-8 | ALSH-8DX | 8/760 | 115 | 7.2/828 | 6″ Union | 200 | 133 | 100 | 75 | 50 |
Note:
A maximum water flow rate (gpm) at uv intensity – μwsec/cm2 @90% (transmissiblity 85% at end of lamp life)
B water velocities greater than 5ft / sec.
* all dimensions are approximate and can change at any time.
* alsv-6-lt and alsv-8-lt models have two plug-in ballast.
* flow rates based on “End of life” lamp output of 85% at 9000 hours.
* add -lt or -dx to part number to select power option desired.
* all units 50 psig maximum operating pressure.
* other water connections sizes are available.
Sun Spot UV Sterilizers | |||||||||||
Model No. | Lamp/Watts | Volts/phase | Amps/watts | Water inlet/Outlet | Maximum Water Flow Rate (GPM) at UV Intensity µWsec/cm2 @90% transmissibility 85% at end of lamp life | ||||||
15k | 20k | 30k | 45k | 60k | 90k | 120k | |||||
ALCMUV-2 | 2/180 | 115 | 1.8/207 | 2″ FPT | 100 | 75 | 50 | 33 | 25 | 16 | 13 |
ALCMUV-3 | 3/285 | 115 | 3/345 | 3″ Union | 150 | 113 | 75 | 50 | 37 | 25 | 18 |
ALCMUV-4 | 4/380 | 115 | 3.6/414 | 3″ Union | 200 | 150 | 100 | 67 | 50 | 37 | 25 |
ALCMUV-6 | 6/570 | 115 | 5/575 | 4″ Union | 300 | 225 | 150 | 100 | 75 | 50 | 33 |
ALCMUV-8 | 8/760 | 115 | 6/690 | 4″ Union | 400 | 300 | 200 | 133 | 100 | 75 | 50 |
Note:
A maximum water flow rate (gpm) at uv intensity – μwsec/cm2 @90% (transmissiblity 85% at end of lamp life)
* all dimensions are approximate and can change at any time.
* the uv width with be determined by the water connection size.
* the water connection is determined by the water flow rate.
Comet UV Sterilizer | Optional Fiberglass Mounting Bracket Part No. | |||||||||
Model No. | Lamp/Watts | Volts/phase | Amps/watts | Water inlet/Outlet | Maximum Water Flow Rate (GPM) at UV Intensity µWsec/cm2 @90% transmissibility 85% at end of lamp life | |||||
30k | 45k | 60k | 90k | 120k | ||||||
ALSLT-95-4 | 1/95 | 115 | .9/104 | 1 1/2″ FPT | 25 | 17 | 13 | 8 | 6 | UV-MB-4 |
ALSLT-95-6 | 1/95 | 115 | .9/104 | 1 1/2″ Union | 35 | 23 | 18 | 12 | 9 | UV-MB-6 |
ALSLT-190-6 | 2/190 | 115 | 1.8/207 | 2″ Union | 70 | 46 | 36 | 24 | 18 | UV-MB-6 |
ALSLT-190-8 | 2/190 | 115 | 1.8/207 | 3″ Union | 110 | 73 | 55 | 36 | 28 | UV-MB-8 |
Note:
A maximum water flow rate (gpm) at uv intensity – μwsec/cm2 @90% (transmissiblity 85% at end of lamp life)
B water velocities greater than 5ft / sec.
* all dimensions are approximate and can change at any time.
* maximum working pressure for all units is 35 psi.