0 $0.00

Resources

Product Sizing, Specifications, Drawings, Literature and More.
Cyclone Chiller
Sizing

Use the tables below to determine the appropriate Cyclone Chiller model for your application.

Please note that the tables make the following assumptions;

  • Calculations based on a closed recirculating system with chiller running full time.
  • Calculations based on a simple system with one pump, 3x per hour water turnover rate, and fluorescent lighting.
  • Do not take into account, multiple pumps, protein skimmers, high intensity lighting, or other such variables.

 

Sizing Table 1-Uninsulated Tanks: Acrylic and Glass.
Note: For Polypropylene/ethylene multiply gallons x 0.8= net gallons.

Temperature “chill down” from ambient (oF) per tank volume (US Gallons)

Cyclone Drop-in Chillers

Model No.

HP

Nominal BTUH

Volts/phase

Amps

Watts

Water flow (GPM)

Air output (CFM)

L (in.)

W (in.)

H (in.)

Coil Length (in.)

Coil Height (in.)

Shipping Weight (lbs.)

Shipping Dimensions (in.)

CY-3

1/4

3000

115

5.4

621

8 – 15

240

17.5

13.5

11.25

7.25

2.125

53

26 x 16 x 15

CY-4

1/3

4000

115

7.2

828

10 – 20

260

17.5

13.5

11.25

9

2.125

62

26 x 16 x 15

CY-5

1/2

6000

115

9.5

1092

12 – 25

350

17.5

15.25

13.125

9.125

3

110

33 x 26 x 24

CY-6

1/2

6000

230/1

4.8

1104

12 – 25

350

17.5

15.25

13.125

9.124

3

112

33 x 26 x 24

Specifications

*Add “CWCT” (cold water cap tube) to model # for desired water temps between 50-65F on available models.

Standard

  • Ideal for tropical aquariums and warm water exhibits, or research applications.
  • Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
  • Amount of refrigerant does not need to change since the water temperature is being maintained at a constant.

‘CWCT’ (Cold Water Cap Tube)

  • Allows for a lower, but more limited temperature range.
  • Ideal for bait fish holding, temperate fish exhibits, and hydroponics.
  • Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
  • Amount of refrigerant does not need to change since the water temperature is being maintained at a constant.
Delta Star in-line Chillers
Sizing

The following tables can be used to determine the appropriate Delta Star Chiller Model chiller for your application.

Tables display the maximum water volume (Gallons) that can be maintained at a range of temperature differences below the ambient air temperature. Please note that the tables make the following assumptions, and that for more accurate sizing or complex systems you should contact Aqua Logic for assistance:

  • Calculations based on a closed recirculating system with chiller running full time.
  • Calculations based on a simple system with one pump, 3x per hour water turnover rate, and fluorescent lighting.
  • Please consult Aqua Logic for proper sizing if using multiple pumps, protein skimmers, high intensity lighting, or other such variables.

Sizing Table 1-Uninsulated Tanks: Acrylic and Glass. Note: For Polypropylene/ethylene multiply gallons x 0.8= net gallons.

Temperature “chill down” from ambient (oF) per tank volume (US Gallons)

Delta Star® Air-Cooled Chillers

MODEL

HP

BTUH REMOVAL CAPACITY

VOLTS/PHASE

AMPS

FLOW (GPM) MIN/MAX

IN/OUT FIPT (IN)

LENGTH (IN)

WIDTH (IN)

HEIGHT (IN)

SHIPPING WEIGHT (LBS)

DS-3

1/4

3,000

115

5.4

8/15

3/4″

22 1/2″

13 1/2″

11 1/4″

62 lbs.

DS-4

1/3

4,000

115

7.2

10/20

3/4″

22 1/2″

13 1/2″

11 1/4″

62 lbs.

DS-5

1/2

6,000

115

9.5

12/25

1-1/2″

24″

15 1/4″

13 1/8″

110 lbs.

DS-6

1/2

6,000

230

4.8

12/25

1-1/2″

24″

15 1/4″

13 1/8″

112 lbs.

DS-7

3/4

9,500

115

15.4

15/30

1-1/2″

25″

24″

14 3/4″

145 lbs.

DS-8

3/4

9,500

230

8.4

15/30

1-1/2″

25″

24″

14 3/4″

145 lbs.

DS-9

1

12,000

230

9

20/35

1-1/2″

26 1/2″

28″

17 3/4″

150 lbs.

DS-10

1 1/2

21,000

230

10.5

25/40

1-1/2″

26 1/4″

26″

17 1/2″

190 lbs.

Specifications

*Add “CWCT” (cold water cap tube) to model # for desired water temps between 50-65F on available models.

*Add “TXV” to model # for lower desired water temps between 40-80F on available models.

Standard

  • Ideal for tropical aquariums and warm water exhibits, or research applications.
  • Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
  • Amount of refrigerant does not need to change since the water temperature is being maintained at a constant.

‘CWCT’ (Cold Water Cap Tube)

  • Allows for a lower, but more limited temperature range.
  • Ideal for bait fish holding, temperate fish exhibits, and hydroponics.
  • Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
  • Amount of refrigerant does not need to change since the water temperature is being maintained at a constant.

“TXV” (Thermal Expansion Valve)

  • Provides both the lowest water temperature and the most broad temperature range.
  • Required for applications where the unit will need to maintain a very cold temperature.
  • Ideal for lobster tanks, cold water fish exhibits, or research applications.
  • The thermal expansion valve constantly regulates the amount of refrigerant going to the heat exchanger based on the desired water temperature.

We will be happy to assist you in choosing the correct chiller for your application. Please Request a Quote and provide us with your information.

 

Multi-Temp Chillers
Sizing

A number of factors influence the correct size of chiller required for your application. While standard Btu calculations can be applied, and our Multi Temp Chiller Specifications can offer some guidelines, the parameters of your application will be the deciding factor in correct size selection. Contact us today for help with sizing the perfect unit for your needs.

For spatial planning you can refer to the dimensions of each unit on our specifications table and use the following diagram as a guide. Custom sizes available.

Multi-Temp Chillers – Air Cooled

Model No.

Nominal Tons

Nominal BTUH

Volts/phase

Amps RLA/LRA

Water flow (GPM)

Air Outlet (CFM)

H (In.)

L (in.)

W (In.)

Shipping Weight (lbs.)

MT-1

2

24000

208-240/1


11/63

20 – 40

1282

59

44

33

370

MT-3

3

36000

208-240/1

18/77

20 – 40

2615

63

44

33

396

MT-4

3

36000

208-240/3

10/71

20 – 40

2615

66

44

33

386

MT-4-460

3

36000

460/3

6/38

20 -40

2615

66

44

33

386

MT-5

4

48000

208-240/1

23/124

30 – 60

2615

59

51

38

474

MT-6

4

48000

208-240/3

15/83

30 – 60

2615

63

51

38

474

MT-6-460

4

48000

460/3

7/41

30 – 60

2615

63

51

38

474

MT-7

5

60000

208-240/1

27/153

30 – 60

2785

70

51

38

520

MT-8

5

60000

208-240/3

17/110

30 – 60

2785

70

51

38

528

MT-8-460

5

60000

460/3

8/52

30 – 60

2785

70

51

38

528

MT-9

7.5

90000

208-240/3

28/164

60 – 120

5100

68

51

42

670

MT-9-460

7.5

90000

460/3

15/100

60 – 120

5100

68

51

42

670

MT-10

10

120000

208-240/3

35/225

60 – 120

7500

68

61

46

815

MT-10-460

10

120000

460/3

19/114

60 – 120

7500

68

61

46

815

MT-12

12

150000

208-240/3

50/149

60 – 120

7800

74

61

46

965

MT-12-460

12

150000

460/3

27/75

60 – 120

7800

74

61

46

965

MT-15

15

180000

208-240/3

50/164

120 – 180

9750

78

111.5

53

1559

MT-15-460

15

180000

460/3

25/100

120 – 180

9750

78

111.5

53

1559

MT-20

20

240000

208-240/3

78/267

120 – 180

9750

91

111.5

53

1714

MT-20-460

20

240000

460/3

40/142

120 – 180

9750

91

111.5

53

1714

MT-25

25

300000

208-240/3

82/267

120 – 180

15500

75

122

53

2000

MT-20-460

25

300000

460/3

40/142

120 – 180

15500

75

122

53

2000

 

Specifications
  • 2 Hp – 25 Hp
  • Insulated Titanium Heat Exchanger
  • TRANE Condensing Unit
  • Dual Stage Digital Temperature Controller in NEMA4X enclosure
  • Built in Safety Flow Switch
  • Automatic Temperature Ranging
  • Temperature Range down to 40ºF
  • Includes stainless steel stand
  • Fresh or Saltwater use
  • All units suitable for outdoor use
  • One-year warranty
  • Allow 2 weeks for delivery
  • Ships motor freight from factory
  • Made in USA
Multi-Temp Chillers Water-Cooled
Sizing

A number of factors influence the correct size of chiller required for your application. While standard Btu calculations can be applied, and our Multi Temp Chiller Specifications can offer some guidelines, the parameters of your application will be the deciding factor in correct size selection. Contact us today for help with sizing the perfect unit for your needs.

For spatial planning you can refer to the dimensions of each unit on our specifications table and use the following diagram as a guide. Custom sizes available.

Multi-temp Chillers Water-Cooled

Model No.

Nominal Tons

Nominal BTUH

Volts/phase

Condenser Water flow (GPM)

Evaporator Water flow (GPM)

H (In.)

L (in.)

W (In.)

MT-1-WC

2

24000

208-240/1

2 – 4

20 – 40

34

39.5

20

MT-3-WC

3

36000

208-240/1

2 – 5

20 – 40

41

39.5

20

MT-4-WC

3

36000

208-240/3

2 – 5

20 – 40

41

39.5

20

MT-4-460-WC

3

36000

460/3

2 – 5

20 – 40

41

39.5

20

MT-5-WC

4

48000

208-240/1

3 – 7

30 – 60

49

39.5

20

MT-6-WC

4

48000

208-240/3

3 – 7

30 – 60

49

39.5

20

MT-6-460-WC

4

48000

460/3

3 – 7

30 – 60

49

39.5

20

MT-7-WC

5

60000

208-240/1

4 – 8

30 – 60

56.5

39.5

20

MT-8-WC

5

60000

208-240/3

4 – 8

30 – 60

56.5

39.5

20

MT-8-460-WC

5

60000

460/3

4 – 8

30 – 60

56.5

39.5

20

MT-9-WC

7.5

90000

208-240/3

9

60 – 120

63.38

39.5

20

MT-9-460-WC

7.5

90000

460/3

9

60 – 120

63.38

39.5

20

MT-10-WC

10

120000

208-240/3

9

60 – 120

63.38

39.5

20

MT-10-460-WC

10

120000

460/3

9

60 – 120

63.38

39.5

20

MT-15-WC

15

180000

208-240/3

13

120 – 180

72.25

55

20

MT-15-460-WC

15

180000

460/3

13

120 – 180

72.25

55

20

MT-20-WC

20

240000

208-240/3

17

120 – 180

81.5

55

20

MT-20-460-WC

20

240000

460/3

17

120 – 180

81.5

55

20

MT-20-WC

25

300000

208-240/3

17

120 – 180

81.5

55

20

MT-20-460-WC

25

300000

460/3

17

120 – 180

81.5

55

20

Specifications
  • 2 Hp- 25 Hp
  • Insulated Titanium Heat Exchanger
  • In-Line Tube In Shell Evaporator
  • Remote Helix Titanium Coil
  • Water Control Valve for condenser
  • Remote Electronic Temperature Controller
  • Includes Stainless Steel Frame
  • Fresh or Saltwater Use
  • Compact Design
  • Quiet Operation
  • Black ABS Cover
  • Options for size and configuration
  • Ozone Friendly Refrigerant (134A)

CONNECT WITH OUR EXPERT TEAM