Resources
Product Sizing, Specifications, Drawings, Literature and More.
Chillers
Cyclone Series
Sizing
Use the tables below to determine the appropriate Cyclone Chiller model for your application.
Please note that the tables make the following assumptions:
Calculations are based on a closed recirculating system with chiller running full time.
Does not take into account, multiple pumps, protein skimmers, high intensity lighting, or other such variables.
Cyclone Drop-in Chillers | ||||||||||||||
Model No. | HP | Nominal BTUH | Volts/phase | Amps | Watts | Water flow (GPM) | Air output (CFM) | L (in.) | W (in.) | H (in.) | Coil Length (in.) | Coil Height (in.) | Shipping Weight (lbs.) | Shipping Dimensions (in.) |
CY-3 | 1/4 | 3000 | 115 | 5.4 | 621 | 8 - 15 | 240 | 17.5 | 13.5 | 11.25 | 7.25 | 2.125 | 53 | 26 x 16 x 15 |
CY-4 | 1/3 | 4000 | 115 | 7.2 | 828 | 10 - 20 | 260 | 17.5 | 13.5 | 11.25 | 9 | 2.125 | 62 | 26 x 16 x 15 |
CY-5 | 1/2 | 6000 | 115 | 9.5 | 1092 | 12 - 25 | 350 | 17.5 | 15.25 | 13.125 | 9.125 | 3 | 110 | 33 x 26 x 24 |
CY-6 | 1/2 | 6000 | 230/1 | 4.8 | 1104 | 12 - 25 | 350 | 17.5 | 15.25 | 13.125 | 9.124 | 3 | 112 | 33 x 26 x 24 |
Specifications
Standard
Ideal for tropical aquariums and warm water exhibits, or research applications.
Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
Amount of refrigerant does not need to change since the water temperature is being maintained at a constant.
‘CWCT’ (Cold Water Cap Tube)
*Add “CWCT” (cold water cap tube) to the model # for desired water temps between 50-65F on available models.*
Allows for a lower, but more limited temperature range.
Ideal for bait fish holding, temperate fish exhibits, and hydroponics.
Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
Amount of refrigerant does not need to change since the water temperature is being maintained at a constant.
Product Literature
Cyclone Plus
Sizing
Use the table below for sizing info for the CY Plus.
Please note that the table makes the following assumptions:
Calculations are based on a closed recirculating system with the chiller running full time.
Does not take into account multiple pumps, protein skimmers, high-intensity lighting, or other such variables.
Specification | CY-Plus |
Model no. | CYP007 |
Nominal capacity | 1/2 HP+ / 7,000 BTU/H / 2.05 kW |
Compressor | 1/2 HP rotary |
Refrigerant | R-454B (A2L), 10 oz charge |
Electrical | 115V / 1 Ph / 60 Hz |
Compressor amps | 5.9 RLA / 35 LRA |
Fan amps | 0.5 FLA |
Power cord | 6 ft, NEMA 5-15P plug |
Air output | 380 CFM |
Condenser | Aluminum microchannel (MCHE) |
Heat exchanger | Titanium drop-in coil, flexible hose |
Coil size | 9 1/8" L × 3 1/2" H |
Hose length | 72 in (6 ft) |
Water flow across coil | Ensure minimum flow across the coil |
Water level over coil | 6" min. / 8" max. |
Control | Digital with voltage protection, fan-failure alarm, and dirty-condenser alarm |
Cabinet cover | 304 stainless steel |
Cabinet dimensions | 14 3/4" W × 18 1/4" D × 14 1/2" H |
Shipping dimensions | 30 1/2" × 18 1/2" × 18 1/2" |
Ambient air temperature | 45°F – 100°F |
Weight | 57 lbs. |
Specifications
“TXV” (Thermal Expansion Valve)
Provides both the lowest water temperature and the most broad temperature range.
Required for applications where the unit will need to maintain a very cold temperature.
Ideal for lobster tanks, cold water fish exhibits, or research applications.
The thermal expansion valve constantly regulates the amount of refrigerant going to the heat exchanger based on the desired water temperature.
Product Literature
Delta-Star Series Inline Air-Cooled Chillers
Sizing
The following table can be used to determine the appropriate Delta Star Chiller Model for your application.
The table displays the maximum water volume (Gallons) that can be maintained at a range of temperature differences below the ambient air temperature. Please note that the tables make the following assumptions, and that for more accurate sizing or complex systems you should contact Aqua Logic for assistance:
Calculations based on a closed recirculating system with chiller running full time.
Please consult Aqua Logic for proper sizing if using multiple pumps, protein skimmers, high intensity lighting, or other such variables.
Delta Star® Air-Cooled Chillers | ||||||||||
MODEL | HP | BTUH REMOVAL CAPACITY | VOLTS/PHASE | AMPS | FLOW (GPM) MIN/MAX | IN/OUT FIPT (IN) | LENGTH (IN) | WIDTH (IN) | HEIGHT (IN) | SHIPPING WEIGHT (LBS) |
DS-3 | 1/4 | 3,000 | 115 | 5.4 | 8/15 | 3/4" | 22 1/2" | 13 1/2" | 11 1/4" | 62 lbs. |
DS-4 | 1/3 | 4,000 | 115 | 7.2 | 10/20 | 3/4" | 22 1/2" | 13 1/2" | 11 1/4" | 62 lbs. |
DS-5 | 1/2 | 6,000 | 115 | 9.5 | 12/25 | 1-1/2" | 24" | 15 1/4" | 13 1/8" | 110 lbs. |
DS-6 | 1/2 | 6,000 | 230 | 4.8 | 12/25 | 1-1/2" | 24" | 15 1/4" | 13 1/8" | 112 lbs. |
DS-7 | 3/4 | 9,500 | 115 | 15.4 | 15/30 | 1-1/2" | 25" | 24" | 14 3/4" | 145 lbs. |
DS-8 | 3/4 | 9,500 | 230 | 8.4 | 15/30 | 1-1/2" | 25" | 24" | 14 3/4" | 145 lbs. |
DS-9 | 1 | 12,000 | 230 | 9 | 20/35 | 1-1/2" | 26 1/2" | 28" | 17 3/4" | 150 lbs. |
DS-10 | 1 1/2 | 21,000 | 230 | 10.5 | 25/40 | 1-1/2" | 26 1/4" | 26" | 17 1/2" | 190 lbs. |
Specifications
Standard
Ideal for tropical aquariums and warm water exhibits, or research applications.
Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
Amount of refrigerant does not need to change since the water temperature is being maintained at a constant.
‘CWCT’ (Cold Water Cap Tube)
*Add “CWCT” (cold water cap tube) to model # for desired water temps between 50-65F on available models.*
Allows for a lower, but more limited temperature range.
Ideal for bait fish holding, temperate fish exhibits, and hydroponics.
Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
The amount of refrigerant does not need to change since the water temperature is being maintained at a constant.
“TXV” (Thermal Expansion Valve)
*Add “TXV” to model # for lower desired water temps between 40-80F on available models.*
Provides both the lowest water temperature and the most broad temperature range.
Required for applications where the unit will need to maintain a very cold temperature.
Ideal for lobster tanks, cold water fish exhibits, or research applications.
The thermal expansion valve constantly regulates the amount of refrigerant going to the heat exchanger based on the desired water temperature.
Delta-Star Plus
Sizing
The following table can be used to determine the appropriate Delta Star Chiller Model for your application.
The table displays the maximum water volume (Gallons) that can be maintained at a range of temperature differences below the ambient air temperature. Please note that the tables make the following assumptions, and that for more accurate sizing or complex systems you should contact Aqua Logic for assistance:
- Calculations based on a closed recirculating system with chiller running full time.
- Please consult Aqua Logic for proper sizing if using multiple pumps, protein skimmers, high intensity lighting, or other such variables.
Specification | DS Plus |
Model | DSP007 |
Nominal capacity | 7,000 BTU/H |
Compressor | 1/2+ HP |
Refrigerant | R-454B |
Electrical | 120V / 1 Phase |
Power cord | 6 ft, NEMA 5-15P plug |
Fan air output | 1,708 CFM |
Evaporator | Titanium tube in PVC shell |
Water connections | 1" FPT inlet and outlet |
Water flow | 12 - 25 GPM |
Water pressure drop | 2 PSIG |
Water temperature range | 40°F – 80°F |
Ambient air temperature | 35°F – 100°F |
Control | Digital, short-cycle protection |
Cabinet | 304 Stainless Steel with marine coating |
Cabinet dimensions | 14 3/4" W × 18 1/4" D × 14 1/2" H |
Shipping dimensions | 30 1/2" × 18 1/2" × 18 1/2" |
Air clearance | 12" minimum, inlet and outlet |
Weight | 58 lbs |
Specifications
“TXV” (Thermal Expansion Valve)
Provides both the lowest water temperature and the most broad temperature range.
Required for applications where the unit will need to maintain a very cold temperature.
Ideal for lobster tanks, cold water fish exhibits, or research applications.
The thermal expansion valve constantly regulates the amount of refrigerant going to the heat exchanger based on the desired water temperature.
Product Literature
Delta-Star Series Inline Water-Cooled Chillers
Sizing
The following table can be used to determine the appropriate Delta Star Chiller Model for your application.
The table displays the maximum water volume (Gallons) that can be maintained at a range of temperature differences below the ambient air temperature. Please note that the tables make the following assumptions, and that for more accurate sizing or complex systems you should contact Aqua Logic for assistance:
Calculations based on a closed recirculating system with chiller running full time.
Please consult Aqua Logic for proper sizing if using multiple pumps, protein skimmers, high-intensity lighting, or other such variables.
Delta-Star in-line Water-Cooled Chillers | |||||||||||||
Model No. | Rev. | Refrigerant | Nominal BTUH | HP | Volts | Phase | Amps | Water flow (GPM) | Condenser water flow (GPM) | In/Out (FIPT in) | L (in.) | W (in.) | H (in.) |
DS-3-WC | B | 513a | 3000 | 1/4 | 115 | 1 | 5.4 | 8 - 15 | 0.30 | 3/4 | 22.5 | 13.5 | 11.25 |
DS-4-WC | B | 513a | 4000 | 1/3 | 115 | 1 | 7.2 | 10 - 20 | 0.5 | 3/4 | 22.5 | 13.5 | 11.25 |
DS-5-WC | B | 513a | 6000 | 1/2 | 115 | 1 | 9.5 | 12 - 25 | 0.7 | 1 1/2 | 24 | 15.25 | 13.125 |
DS-6-WC | B | 513a | 6000 | 1/2 | 230 | 1 | 4.8 | 12 - 25 | 0.7 | 1 1/2 | 24 | 15.25 | 13.125 |
DS-7-WC | B | 513a | 9500 | 3/4 | 115 | 1 | 13 | 15 - 30 | 1 | 1 1/2 | 25 | 24 | 14.75 |
DS-8-WC | B | 513a | 9500 | 3/4 | 230 | 1 | 7 | 15 - 30 | 1 | 1 1/2 | 25 | 24 | 14.75 |
DS-9-WC | B | 513a | 12000 | 1 | 230 | 1 | 7.2 | 20 - 35 | 1.5 | 1 1/2 | 26.5 | 28 | 17.75 |
DS-10-WC | B | 513a | 15000 | 1 1/2 | 230 | 1 | 10.8 | 25 - 40 | 2 | 1 1/2 | 28.625 | 27.5 | 22.375 |
DS-10-WC | D | 404a | 22000 | 1 1/2 | 230 | 1 | 10.8 | 25 - 40 | 2 | 1 1/2 | 28.625 | 27.5 | 22.375 |
Specifications
Standard
Ideal for tropical aquariums and warm water exhibits, or research applications.
Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
Amount of refrigerant does not need to change since the water temperature is being maintained at a constant.
‘CWCT’ (Cold Water Cap Tube)
*Add “CWCT” (cold water cap tube) to model # for desired water temps between 50-65F on available models.*
Allows for a lower, but more limited temperature range.
Ideal for bait fish holding, temperate fish exhibits, and hydroponics.
Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
The amount of refrigerant does not need to change since the water temperature is being maintained at a constant.
“TXV” (Thermal Expansion Valve)
*Add “TXV” to model # for lower desired water temps between 40-80F on available models.*
Provides both the lowest water temperature and the most broad temperature range.
Required for applications where the unit will need to maintain a very cold temperature.
Ideal for lobster tanks, cold water fish exhibits, or research applications.
The thermal expansion valve constantly regulates the amount of refrigerant going to the heat exchanger based on the desired water temperature.
Multi-Temp Series Air-Cooled Packaged and Split
Sizing
A number of factors influence the correct size of chiller required for your application. While standard BTU calculations can be applied, and our Multi-Temp Chiller Specifications can offer some guidelines, the parameters of your application will be the deciding factor in correct size selection. Contact us today for help with sizing the perfect unit for your needs.
For spatial planning you can refer to the dimensions of each unit on our specifications table and use the following diagram as a guide. Custom sizes available.
Multi-Temp Series Air-Cooled | ||||||||||
Model No. | Nominal Tons | Nominal BTUH | Volts/phase | Amps RLA/LRA | Water flow (GPM) | Air Outlet (CFM) | H (In.) | L (in.) | W (In.) | Shipping Weight (lbs.) |
MT-1 | 2 | 24000 | 208-240/1 | 11/63 | 20 - 40 | 1282 | 59 | 44 | 33 | 370 |
MT-3 | 3 | 36000 | 208-240/1 | 18/77 | 20 - 40 | 2615 | 63 | 44 | 33 | 396 |
MT-4 | 3 | 36000 | 208-240/3 | 10/71 | 20 - 40 | 2615 | 66 | 44 | 33 | 386 |
MT-4-460 | 3 | 36000 | 460/3 | 6/38 | 20 -40 | 2615 | 66 | 44 | 33 | 386 |
MT-5 | 4 | 48000 | 208-240/1 | 23/124 | 30 - 60 | 2615 | 59 | 51 | 38 | 474 |
MT-6 | 4 | 48000 | 208-240/3 | 15/83 | 30 - 60 | 2615 | 63 | 51 | 38 | 474 |
MT-6-460 | 4 | 48000 | 460/3 | 7/41 | 30 - 60 | 2615 | 63 | 51 | 38 | 474 |
MT-7 | 5 | 60000 | 208-240/1 | 27/153 | 30 - 60 | 2785 | 70 | 51 | 38 | 520 |
MT-8 | 5 | 60000 | 208-240/3 | 17/110 | 30 - 60 | 2785 | 70 | 51 | 38 | 528 |
MT-8-460 | 5 | 60000 | 460/3 | 8/52 | 30 - 60 | 2785 | 70 | 51 | 38 | 528 |
MT-9 | 7.5 | 90000 | 208-240/3 | 28/164 | 60 - 120 | 5100 | 68 | 51 | 42 | 670 |
MT-9-460 | 7.5 | 90000 | 460/3 | 15/100 | 60 - 120 | 5100 | 68 | 51 | 42 | 670 |
MT-10 | 10 | 120000 | 208-240/3 | 35/225 | 60 - 120 | 7500 | 68 | 61 | 46 | 815 |
MT-10-460 | 10 | 120000 | 460/3 | 19/114 | 60 - 120 | 7500 | 68 | 61 | 46 | 815 |
MT-12 | 12 | 150000 | 208-240/3 | 50/149 | 60 - 120 | 7800 | 74 | 61 | 46 | 965 |
MT-12-460 | 12 | 150000 | 460/3 | 27/75 | 60 - 120 | 7800 | 74 | 61 | 46 | 965 |
MT-15 | 15 | 180000 | 208-240/3 | 50/164 | 120 - 180 | 9750 | 78 | 111.5 | 53 | 1559 |
MT-15-460 | 15 | 180000 | 460/3 | 25/100 | 120 - 180 | 9750 | 78 | 111.5 | 53 | 1559 |
MT-20 | 20 | 240000 | 208-240/3 | 78/267 | 120 - 180 | 9750 | 91 | 111.5 | 53 | 1714 |
MT-20-460 | 20 | 240000 | 460/3 | 40/142 | 120 - 180 | 9750 | 91 | 111.5 | 53 | 1714 |
MT-25 | 25 | 300000 | 208-240/3 | 82/267 | 120 - 180 | 15500 | 75 | 122 | 53 | 2000 |
MT-20-460 | 25 | 300000 | 460/3 | 40/142 | 120 - 180 | 15500 | 75 | 122 | 53 | 2000 |
Specifications
Insulated Titanium Heat Exchanger
Dual-Stage Digital Temperature Controller in NEMA 4X enclosure
Built-in Safety Flow Switch
Temperature Range down to 40ºF
Includes stainless-steel stand
Fresh or Saltwater use
All units suitable for outdoor use
Made in the USA
Product Literature
MT-1 through MT-8 Instructions
MT-9 through MT-20 Instructions
MT-25 through MT-40 Instructions
MT-1 through MT-8 Packaged Specification Sheet
MT-9 through MT-12 Packaged Specification Sheet
MT-15 through MT-20 Packaged Specification Sheet
MT-25 Packaged Specification Sheet
MT-30 Packaged Specification Sheet
MT-40 Packaged Specification Sheet
MT-60 Packaged Specification Sheet
MT-1 through MT-8 Split Specification Sheet
MT-9 through MT-10 Split Rheem Specification Sheet
MT-9 through MT-10 Split Trane Specification Sheet
MT-10 through MT-20 Split Rheem Specification Sheet
MT-10 through MT-20 Split Trane Specification Sheet
MT-25 Split Specification Sheet
MT-30 Split Specification Sheet
Multi-Temp Series Water-Cooled Chillers
Sizing
A number of factors influence the correct size of chiller required for your application. While standard BTU calculations can be applied, and our Multi-Temp Chiller Specifications can offer some guidelines, the parameters of your application will be the deciding factor in correct size selection. Contact us today for help with sizing the perfect unit for your needs.
For spatial planning you can refer to the dimensions of each unit on our specifications table and use the following diagram as a guide. Custom sizes available.
Multi-Temp Series Water-Cooled Chillers | ||||||||
Model No. | Nominal Tons | Nominal BTUH | Volts/phase | Condenser Water flow (GPM) | Evaporator Water flow (GPM) | H (In.) | L (in.) | W (In.) |
MT-1-WC | 2 | 24000 | 208-240/1 | 2 - 4 | 20 - 40 | 34 | 39.5 | 20 |
MT-3-WC | 3 | 36000 | 208-240/1 | 2 - 5 | 20 - 40 | 41 | 39.5 | 20 |
MT-4-WC | 3 | 36000 | 208-240/3 | 2 - 5 | 20 - 40 | 41 | 39.5 | 20 |
MT-4-460-WC | 3 | 36000 | 460/3 | 2 - 5 | 20 - 40 | 41 | 39.5 | 20 |
MT-5-WC | 4 | 48000 | 208-240/1 | 3 - 7 | 30 - 60 | 49 | 39.5 | 20 |
MT-6-WC | 4 | 48000 | 208-240/3 | 3 - 7 | 30 - 60 | 49 | 39.5 | 20 |
MT-6-460-WC | 4 | 48000 | 460/3 | 3 - 7 | 30 - 60 | 49 | 39.5 | 20 |
MT-7-WC | 5 | 60000 | 208-240/1 | 4 - 8 | 30 - 60 | 56.5 | 39.5 | 20 |
MT-8-WC | 5 | 60000 | 208-240/3 | 4 - 8 | 30 - 60 | 56.5 | 39.5 | 20 |
MT-8-460-WC | 5 | 60000 | 460/3 | 4 - 8 | 30 - 60 | 56.5 | 39.5 | 20 |
MT-9-WC | 7.5 | 90000 | 208-240/3 | 9 | 60 - 120 | 63.38 | 39.5 | 20 |
MT-9-460-WC | 7.5 | 90000 | 460/3 | 9 | 60 - 120 | 63.38 | 39.5 | 20 |
MT-10-WC | 10 | 120000 | 208-240/3 | 9 | 60 - 120 | 63.38 | 39.5 | 20 |
MT-10-460-WC | 10 | 120000 | 460/3 | 9 | 60 - 120 | 63.38 | 39.5 | 20 |
MT-15-WC | 15 | 180000 | 208-240/3 | 13 | 120 - 180 | 72.25 | 55 | 20 |
MT-15-460-WC | 15 | 180000 | 460/3 | 13 | 120 - 180 | 72.25 | 55 | 20 |
MT-20-WC | 20 | 240000 | 208-240/3 | 17 | 120 - 180 | 81.5 | 55 | 20 |
MT-20-460-WC | 20 | 240000 | 460/3 | 17 | 120 - 180 | 81.5 | 55 | 20 |
MT-20-WC | 25 | 300000 | 208-240/3 | 17 | 120 - 180 | 81.5 | 55 | 20 |
MT-20-460-WC | 25 | 300000 | 460/3 | 17 | 120 - 180 | 81.5 | 55 | 20 |
Specifications
Insulated Titanium Heat Exchanger
Inline Tube-in-Shell Evaporator
Water Control Valve for condenser
Remote Electronic Temperature Controller
Includes Stainless-Steel Frame
Fresh or Saltwater Use
Compact Design
Quiet Operation
Black ABS Cover
Various options for sizing and configuration
Product Literature
Multi-Temp Series Water-Cooled Chillers 230V Single-Phase Instructions
Multi-Temp Series Water-Cooled Chillers 230V Three-Phase Instructions
Multi-Temp Series Water-Cooled Chillers 460V Three-Phase Instructions
MT-1-WC through MT-8-WC Horizontal HX Specification Sheet
MT-1-WC through MT-8-WC Vertical HX Specification Sheet
MT-5-WC and MT-6-WC Spa Specification Sheet
MT-9-WC and MT-10-WC Horizontal HX Specification Sheet
MT-9-WC Vertical HX Specification Sheet
MT-10-WC-DE Vertical HX Specification Sheet
MT-15-WC-DE Vertical HX Specification Sheet
MT-20-WC-DE Vertical HX Specification Sheet
MT-25-WC-DE Vertical HX Specification Sheet
Pool & Spa Chiller Series
Sizing
Aqua Logic’s new PSC Pool & Spa Series are commercial water-cooled chillers built to work in enclosed equipment rooms, including the tight spaces beneath hydrotherapy pools. Because they reject heat into condenser water rather than the room air, they can run indoors without overheating the space.
MODEL NO. | 45°F COIL NOMINAL TONS / BTUH / KW | VOLTS / PHASE | AMPS RLA / LRA | WATER FLOW RATE (GPM) | CONDENSER WATER FLOW RATE (GPM) (MIN/MAX) | H | L | W | HEAT EXCHANGER INLET/OUTLET SIZE | CONDENSER INTEL/OUTLET SIZE (FPT) |
PSC024P2 | 2 / 24K / 7 | 208 - 240 / 1 | 17 / 96.7 | 20 / 40 | 2 / 4 | 38.75" | 28" | 26.5" | 1-1/2" | 1/2" |
PSC024P3 | 2 / 24K / 7 | 208 - 240 / 3 | 12.8 / 95 | 20 / 40 | 2 / 4 | 38.75" | 28" | 26.5" | 1-1/2" | 1/2" |
PSC036P2 | 3 / 36K / 10.5 | 208 - 240 / 1 | 21 / 115 | 20 / 40 | 2 / 5 | 38.75" | 28" | 26.5" | 1-1/2" | 1/2" |
PSC036P3 | 3 / 36K / 10.5 | 208 - 240 / 3 | 14.7 / 115 | 20 / 40 | 2 / 5 | 38.75" | 28" | 26.5" | 1-1/2" | 1/2" |
PSC048P2 | 4 / 48K / 14.1 | 208 - 240 / 1 | 26.3 / 150 | 20 / 40 | 3 / 7 | 38.75" | 28" | 26.5" | 1-1/2" | 1/2" |
PSC048P3 | 4 / 48K / 14.1 | 208 - 240 / 3 | 17.6 / 120 | 30 / 60 | 3 / 7 | 38.75" | 28" | 26.5" | 1-1/2" | 1/2" |
PSC060P2 | 5 / 60K / 17.6 | 208 - 240 / 1 | 26.9 / 145 | 30 / 60 | 4 / 8 | 48.25" | 28" | 26.5" | 2" | 3/4" |
PSC060P3 | 5 / 60K / 17.6 | 208 - 240 / 3 | 23 / 160 | 30 / 60 | 4 / 8 | 48.25" | 28" | 26.5" | 2" | 3/4" |
PSC090P3 | 7.5 / 90K / 26.4 | 208 - 240 / 3 | 27.9 / 250 | 30 / 60 | 5 / 9 | 48.25" | 28" | 26.5" | 2" | 3/4" |
Specifications
Nine models cover 2 to 7.5 tons in 208–240V single- and three-phase, using A2L refrigerant R-454B and a titanium helical heat exchanger for fresh or salt water.
Compact 28″ × 26.5″ cabinets with lifting eyelets lower through tight equipment doors.
Condenser water regulating valve shuts off condenser flow when the unit cycles off.
Protection includes electronic high/low pressure cutouts, a high condensing temperature alarm, an integrated flow switch, voltage protection, and refrigerant leak detection.
Made in the United States in Monroe, N.C.
Product Literature
Pool & Spa Chiller Series Instructions
Pool & Spa Chiller Series Specification Sheet
Heat Pumps
Delta-Star Series Air-Cooled Heat Pumps
Sizing
The following table can be used to determine the appropriate Delta Star Heat Pump Model for your application.
The table displays the maximum water volume (Gallons) that can be maintained at a range of temperature differences below the ambient air temperature. Please note that the tables make the following assumptions, and that for more accurate sizing or complex systems you should contact Aqua Logic for assistance:
Calculations based on a closed recirculating system with heat pump running full time.
Please consult Aqua Logic for proper sizing if using multiple pumps, protein skimmers, high-intensity lighting, or other such variables.
Delta-Star Air-Cooled Heat Pump | |||||||||||||
MODEL | HP | NOMINAL | R134A | VOLTS / | AMPS. | WATTS | WATER | AIR | L | W | H | WO | WC |
DSHP-4 | 1/3 | 4,000 | 8.5 | 115 | 7.2 | 828 | 10-20 | 260 | 22 1/2" | 13 5/8" | 14" | 7 1/4" | 3/4" |
DSHP-5 | 1/2 | 6,000 | 10 | 115 | 9.5 | 1092 | 12-25 | 350 | 24" | 15 3/8" | 15 1/2" | 9 1/4" | 1 1/2" |
DSHP-6 | 1/2 | 6,000 | 10 | 230 / 1 | 4.8 | 1104 | 12-25 | 350 | 24" | 15 3/8" | 15 1/2" | 9 1/4" | 1 1/2" |
DSHP-7 | 3/4 | 9500 | R134A / 38 | 115 | 15.4 | 70 | 19.2 | 590 | 23 3/4" | 23 3/4" | 14 7/8" | 9 1/4" | 1 1/2" |
DSHP-8 | 3/4 | 9500 | R134A / 48 | 230 / 1 | 7 | 1610 | 15 - 30 | 590 | 23 3/4" | 23 3/4" | 14 7/8" | 9 1/4" | 1 1/2" |
DSHP-9 | 1 | 12,000 | R134A / 56 | 230 / 1 | 7.2 | 1656 | 20 - 35 | 610 | 26 1/4" | 27 1/2" | 17 5/8" | 9 1/4" | 1 1/2" |
DSHP-10 | 1 1/2 | 21,000 | R404A / 72 | 230 / 1 | 10.5 | 2415 | 25 - 40 | 772 | 26 1/4" | 26 1/4" | 17 5/8" | 12" | 1 1/2" |
Specifications
Features:
Reversible refrigeration cycle provides both cooling and heating in one package
In-line PVC tube-in-shell with titanium heat exchanger coil(s)
Dual-stage electronic temperature controller, NEMA 4X
Temperature range of 40°F – 85°F water
Optional water flow switch
System Requirements:
An external pump is required to move water through the heat exchanger. Pumps are not included.
Heat pumps must not be placed in a confined space, as restricted airflow will damage the unit.
Designed for indoor use.
Titan Series Air-Cooled Heat Pump
Sizing
A number of factors influence the correct size of chiller required for your application. While standard BTU calculations can be applied, and our Titan Heat Pump Specifications can offer some guidelines, the parameters of your application will be the deciding factor in correct size selection. Contact us today for help with sizing the perfect unit for your needs.
For spatial planning you can refer to the dimensions of each unit on our specifications table and use the following diagram as a guide. Custom sizes available.
Titan Air-Cooled Heat Pumps | |||||||||
Model No. | Nominal Tons | Nominal BTUH | Volts/phase | Amps RLA/LRA | Water flow (GPM) | Air Outlet (CFM) | H (In.) | L (in.) | W (In.) |
HP-1 | 1.5 | 18000 | 208-240/1 | 6/38 | 20 - 40 | 1550 | 59 | 44 | 33 |
HP-2 | 2 | 24000 | 208-240/1 | 8.7/57 | 20 - 40 | 1550 | 63 | 44 | 33 |
HP-3 | 3 | 36000 | 208-240/1 | 14/91 | 20 - 40 | 2175 | 63 | 51 | 38 |
HP-33 | 3 | 36000 | 208-240/3 | 10.9/74 | 20 - 40 | 2175 | 63 | 51 | 38 |
HP-33-460 | 3 | 36000 | 460/3 | 5.5/38 | 20 - 40 | 2175 | 63 | 51 | 38 |
HP-4 | 4 | 48000 | 208-240/1 | 18.6/94 | 30 - 60 | 2500 | 67 | 51 | 38 |
HP-43 | 4 | 48000 | 208-240/3 | 13.7/101 | 30 - 60 | 2500 | 67 | 51 | 38 |
HP-43-460 | 4 | 48000 | 460/3 | 7/41 | 30 - 60 | 2500 | 67 | 51 | 38 |
HP-5 | 5 | 60000 | 208-240/1 | 25/148 | 30 - 60 | 3700 | 75 | 51 | 38 |
HP-53 | 5 | 60000 | 208-240/3 | 18.6/94 | 30 - 60 | 3700 | 75 | 51 | 38 |
HP-5-460 | 5 | 60000 | 460/3 | 9/71 | 30 - 60 | 3700 | 75 | 51 | 38 |
HP-6 | 7.5 | 90000 | 208-240/3 | 29/172 | 60 - 120 | 5200 | 65 | 51 | 42 |
HP-6-460 | 7.5 | 90000 | 460/3 | 15/94 | 60 - 120 | 5200 | 65 | 51 | 42 |
HP-7 | 10 | 120000 | 208-240/3 | 40/278 | 60 - 120 | 5200 | 74 | 61 | 46 |
HP-7-460 | 10 | 120000 | 460/3 | 15/90 | 60 - 120 | 5200 | 74 | 61 | 46 |
HP-15 | 15 | 180000 | 208-240/3 | 50/164 | 120 - 180 | 9750 | 78 | 111.5 | 53 |
HP-15-460 | 15 | 180000 | 460/3 | 25/100 | 120 - 180 | 9750 | 78 | 111.5 | 53 |
HP-20 | 20 | 240000 | 208-240/3 | 78/267 | 120 - 180 | 9750 | 91 | 111.5 | 53 |
HP-20-460 | 20 | 240000 | 460/3 | 40/142 | 120 - 180 | 9750 | 91 | 111.5 | 53 |
Specifications
1.5 HP – 20 HP
Heat or Chill with one unit
Insulated Titanium Heat Exchanger
Dual-Stage Digital Temperature Controller in NEMA 4X enclosure
Built-in Safety Flow Switch
Includes stainless-steel stand
Fresh or Saltwater use
All units suitable for outdoor use
Product Literature
HP-1 through HP-5 Packaged Instructions
HP-6 through HP-20 Packaged Instructions
HP-1 through HP-5 Single-Phase Split Instructions
HP-3 through HP-5 Three-Phase Split Instructions
HP-6 through HP-20 Split Instructions
HP-1 through HP-5 Packaged Specification Sheet
HP-6-DE and HP-7-DE Packaged Specification Sheet
HP-20-DE Packaged Specification Sheet
HP-2 through HP-5 Split Specification Sheet
HP-6 and HP-7 Split Specification Sheet
Titan Series Water-Cooled Heat Pump
Sizing
A number of factors influence the correct size of chiller required for your application. While standard BTU calculations can be applied, and our Titan Heat Pump Specifications can offer some guidelines, the parameters of your application will be the deciding factor in correct size selection. Contact us today for help with sizing the perfect unit for your needs.
For spatial planning you can refer to the dimensions of each unit on our specifications table and use the following diagram as a guide. Custom sizes available.
Specifications
2 HP – 25 HP
Heat or Chill with one unit
Insulated Titanium Heat Exchanger
Inline Tube-in-Shell Evaporator
Water Control Valve for condenser
Remote Electronic Temperature Controller
Includes Stainless Steel Frame
Fresh or Saltwater Use
Compact Design
Quiet Operation
Black ABS Cover
Various options for size and configuration
Electric Heaters
Cygnet Series Mini Electric Heaters
Sizing
System Requirements:
Requires an external pump to move water through the heater
Observe the minimum and maximum flow rates to avoid damage to the heater
Pre-filtration and suitable water quality are required to prevent buildup
Maintenance schedule will vary by application, periodic cleaning is the only required maintenance
Cygnet Mini Electric Heaters | |||||
Part No. | Heating Capacity KW | Volts/Phase | Load Amps | Minimum Water Flow (GPM) | In/Out (NPS ABS union) |
AL-KC-0.5-115T | 0.5 | 115/1 | 4.5 | 5 | 1 1/2" |
AL-KC-0.5-115T | 1 | 115/1 | 8.5 | 5 | 1 1/2" |
AL-KC-0.5-115T | 1.5 | 115/1 | 12.75 | 5 | 1 1/2" |
Specifications
3 models in a very compact package from 0.5 kW → 1.5 kW
Easy installation, fully equipped and pre-wired
Reliable flow switch for safe operation
Analogue control thermostat with tight differential
Titanium flow tube and titanium heating element
Saltwater Compatible
EVO Series Electric Heaters
Sizing
System Requirements:
Requires an external pump to move water through the heater
Observe the minimum and maximum flow rates to avoid damage to the heater
Pre-filtration and suitable water quality are required to prevent buildup
Maintenance schedule will vary by application, periodic cleaning is the only required maintenance
EVO Series Electric Heaters | |||||
Part No. | Heating Capacity KW | Volts/phase | Load Amps | Minimum Water flow (GPM) | In/Out (NPS ABS union) |
HSS-1.5-115 | 1.5 | 115 / 1 | 13 | 10 | 1.5" |
HSS-2-115 | 2 | 115 / 1 | 17.4 | 10 | 1.5" |
HSS-2-220 | 2 | 220 - 230 / 1 | 9 | 10 | 1.5" |
HSS-3-220 | 3 | 220 - 230 / 1 | 13.6 | 10 | 1.5" |
HTI-1.5-115 | 1.5 | 115 / 1 | 13 | 10 | 1.5" |
HTI-2-115 | 2 | 115 / 1 | 17.4 | 10 | 1.5" |
HTI-2-220 | 2 | 220 - 230 / 1 | 9 | 10 | 1.5" |
HTI-3-220 | 3 | 220 - 230 / 1 | 13.6 | 10 | 1.5" |
HTI-4-220 | 4 | 220 - 230 / 1 | 18 | 10 | 1.5" |
Specifications
5 models in a compact package from 1.5 kW → 4 kW
115V and 220V options
Reliable flow switch for safe operation
Digital control thermostat with tight differential
Saltwater compatible
Titanium flow tube and coiled titanium heating element
Stay-clean vortex inducing flow over titanium heating element
Optima Compact Plus Series Electric Heaters
Sizing
System Requirements:
Requires an external pump to move water through the heater
Observe the minimum and maximum flow rates to avoid damage to the heater
Pre-filtration and suitable water quality are required to prevent buildup
Maintenance schedule will vary by application, periodic cleaning is the only required maintenance
Optima Compact Plus Electric Heaters | |||||
Part No. | Heating Capacity KW | Volts/phase | Load Amps | Minimum Water flow (GPM) | In/Out (NPS ABS union) |
HTIO-6-220 | 6 | 220 - 230 / 1 | 28 | 10 | 1.5" |
HTIO-8-220 | 8 | 220 - 230 / 1 | 37 | 10 | 1.5" |
HTIO-12-220 | 12 | 220 - 230 / 1 | 55 | 25 | 1.5" |
HTIO-15-220 | 15 | 220 - 230 / 1 | 69 | 25 | 1.5" |
HTIO-18-220 | 18 | 220 - 230 / 1 | 82 | 25 | 1.5" |
HTIO-6-220-3 | 6 | 220 - 230 / 3 | 16 | 10 | 1.5" |
HTIO-8-220-3 | 8 | 220 - 230 / 3 | 22 | 10 | 1.5" |
HTIO-12-220-3 | 12 | 220 - 230 / 3 | 32 | 25 | 1.5" |
HTIO-15-220-3 | 15 | 220 - 230 / 3 | 40 | 25 | 1.5" |
HTIO-18-220-3 | 18 | 220 - 230 / 3 | 48 | 25 | 1.5" |
HTIO-9-460-3 | 9 | 460 - 480 / 3 | 11 - 11.5 | 10 | 1.5" |
HTIO-12-460-3 | 12 | 460 - 480 / 3 | 14.5 - 15 | 10 | 1.5" |
HTIO-17-460-3 | 17.5 | 460 - 480 / 3 | 21 - 22 | 25 | 1.5" |
HTIO-19-460-3 | 19.5 | 460 - 480 / 3 | 23.5 - 24.5 | 25 | 1.5" |
Specifications
14 models in a compact package from 6 kW → 18kW
220–230 V single–phase and three-phase, plus 460V three-phase options
Reliable flow switch for safe operation
Touch screen digital control thermostat with tight differential
Stay-clean vortex inducing flow over titanium heating element
Saltwater Compatible
Titan Optima Series Electric Heaters
Sizing
System Requirements:
Requires an external pump to move water through the heater
Observe the minimum and maximum flow rates to avoid damage to the heater
Pre-filtration and suitable water quality are required to prevent buildup
Maintenance schedule will vary by application, periodic cleaning is the only required maintenance
Specifications
Stay-clean vortex inducing Titanium heating elements
Titanium flow tube; corrosion resistant even with seawater
External reversible flow; allows water flow from either direction
Floor or wall mountable (bracket supplied)
Inlet manifold has been designed to eliminate the risk of air locking
High Limit Thermostat Internal Fail Safe, manual reset thermostat, for positive safety
Touch Screen Digital thermostat with 33ºF differential
Little to no servicing required; Varies with use
Silent Operation
Saltwater compatible
Robust and durable
1 year limited warranty
1½” female thread with supplied:1½” ABS unions for rigid pipe and 1½” x 1¼” hose barb fittings for flexible pipe
Status indicator panel
Dual cascade-wired Schneider contactors
Gas Heaters
ALB Series Gas Heaters
Sizing
For large applications where an electric heater is not practical, turn to our range of gas heaters. Aqua Logic offers our ALB series of gas heaters in both propane and natural gas for indoor or outdoor use. A wide range of capacities is available, with inputs from 84K → 2 million BTUH. The package includes a titanium heat exchanger to ensure you won’t have corrosion or toxic metallic elements leaching into your water.
Specifications
84K → 2 million+ BTUH
Titanium tube heat exchanger for fresh or saltwater use
Available for use with natural gas or propane
Indoor and outdoor applications
Digital LED process water temperature controller
Pre-plumbed and ready to install
Raypac Commercial Boiler with built-in safety controls
Standard temperature range → 65° – 85°F
Product Literature
UV Sterilizers
Comet Series UV Sterilizers
Sizing
A powerful and economical choice for smaller water volumes with low flow rates. Available in four sizes, the Comet can handle up to 165 GPM and can be mounted horizontally or vertically.
Comet UV Sterilizer | Optional Fiberglass Mounting Bracket Part No. | |||||||||
Model No. | Lamp/Watts | Volts/phase | Amps/watts | Water inlet/Outlet | Maximum Water Flow Rate (GPM) at UV Intensity µWsec/cm2 @90% transmissibility 85% at end of lamp life | |||||
30k | 45k | 60k | 90k | 120k | ||||||
ALSLT-95-4 | 1/95 | 115 | .9/104 | 1 1/2" FPT | 25 | 17 | 13 | 8 | 6 | UV-MB-4 |
ALSLT-95-6 | 1/95 | 115 | .9/104 | 1 1/2" Union | 35 | 23 | 18 | 12 | 9 | UV-MB-6 |
ALSLT-190-6 | 2/190 | 115 | 1.8/207 | 2" Union | 70 | 46 | 36 | 24 | 18 | UV-MB-6 |
ALSLT-190-8 | 2/190 | 115 | 1.8/207 | 3" Union | 110 | 73 | 55 | 36 | 28 | UV-MB-8 |
Specifications
5 models in a compact package, 190 – 760 watts
Flow rates up to 300 GPM
Indoor or outdoor use
Corona Series UV Sterilizers
Sizing
Corona UV Sterilizers | ||||||||||
Model No. | Model No. Horizonal | Lamp/Watts | Volts/phase | Amps/watts | Water inlet/Outlet | Maximum Water Flow Rate (GPM) at UV Intensity µWsec/cm2 @90% transmissibility 85% at end of lamp life | ||||
30k | 45k | 60k | 90k | 120k | ||||||
ALSV-2 | ALSH-2DX | 2/190 | 115 | 1.8/207 | 2" FPT | 50 | 33 | 25 | 16 | 13 |
ALSV-3 | ALSH-3DX | 3/285 | 115 | 2.5/287 | 3" Union | 75 | 50 | 37 | 25 | 18 |
ALSV-4 | ALSH-4DX | 4/380 | 115 | 3/345 | 3" Union | 100 | 67 | 50 | 37 | 25 |
ALSV-5 | ALSH-5DX | 5/475 | 115 | 4.5/517 | 4" Union | 150 | 100 | 75 | 50 | 33 |
ALSV-6 | ALSH-6DX | 6/570 | 115 | 5.4/621 | 6" Union | 200 | 133 | 100 | 75 | 50 |
ALSV-8 | ALSH-8DX | 8/760 | 115 | 7.2/828 | 6" Union | 200 | 133 | 100 | 75 | 50 |
Specifications
6 models in a compact package spanning 190 – 760 watts
Convenient vertical and horizontal models to accommodate tight spaces
Flow rates up to 800 GPM
Indoor or outdoor use (if protected from the elements)
220 – 230V in single-phase and three-phase, plus 460V three-phase options
Super Nova Series UV Sterilizers
Sizing
Super Nova UV Sterilizers | |||||||||||
Model No. | Lamp/Watts | Volts/phase | Amps/watts | Chamber Diameter | Water inlet/Outlet | Maximum Water Flow Rate (GPM) at UV Intensity µWsec/cm2 @90% transmissibility 85% at end of lamp life | |||||
30k | 45k | 60k | 90k | 120k | |||||||
ALS-7608.12 | 8/760 | 115 | 6/690 | 12" | 6" flange | 408 | 271 | 204 | 135 | 102 | |
ALS-95010.12 | 10/950 | 115 | 7.5/863 | 12" | 6" flange | 500 | 333 | 250 | 166 | 125 | |
ALS-114012.12 | 12/1140 | 115 | 9/1035 | 12" | 6" flange | 560 | 372 | 280 | 187 | 140 | |
ALS-114012.16 | 12/1140 | 115 | 9.1035 | 16" | 6" flange | 693 | 460 | 346 | 231 | 173 | |
ALS-133014.16 | 14/1330 | 220 | 10.5/1150 | 16" | 8" flange | 780 | 519 | 390 | 260 | 195 | |
ALS-152016.16 | 16/1520 | 220 | 12/1380 | 16" | 8" flange | 876 | 583 | 438 | 292 | 219 | |
Specifications
5 models in a very compact package
Low-pressure, high-output lamps ranging from 95 – 190 watts
Low operating cost
Easy installation and maintenance
Fresh or saltwater
Replacement Parts
Digital Temperature Controllers
Sizing
Aqua Logic’s digital temperature controllers can be used in a variety of applications where a device needs to be turned on / off based on temperature rise or fall.
TR115SN | Digital Controller (single stage) with power cords for 1/4 - 1/2 hp chillers 115v with 7 ft Ti submersible sensor |
TR115DN | Digital Controller (dual stage) with power cords for 1/4 - 1/3 hp chillers & up to 500 watt heater 115v with 7 ft Ti submersible sensor |
TR230SN | Digital Controller (single stage) with power cords for 1/2 hp chiller 230v with 7 ft Ti submersible sensor |
CONT-RAW-TRSN | Digital Controller (single stage) Unwired for 1/4 - 1/2 hp 115v with 7 ft bare sensor |
CONT-RAW-TRDN | Digital Controller (dual stage) Unwired for 2015 and older heat pumps 115 / 230V with 7 ft bare sensor |
DCS-BS | Digital Controller (single stage) for HXW, 115/230V Unwired with 10 ft bare sensor |
DC24S | Digital Controller (single stage) for MT chillers, HX-DX, 24 VAC Unwired with 10 ft bare sensor |
DC24D | Digital Controller (dual stage) for HP heat pump, HX-DXD, 24 VAC |
DCW-115 | Digital Controller 115V Input-24V Output, Temperature controller for water to water heat exchanger packages, HX-4W thru HX-60W. |
DC115S | Digital Controller (single stage) for 1/4 - 1/2 hp 115v with 10 ft Ti submersible sensor |
DC115S-BS | Digital Controller (single stage) with power cords for 1/4 - 1/2 hp 115v with 10 ft bare sensor |
DC115S-20 | Digital Controller (single stage) with power cords for 3/4 hp 115v with 10 ft Ti submersible sensor |
DC115S-20-BS | Digital Controller (single stage) with power cords for 3/4 hp 115v with 10 ft bare sensor |
DC115D | Digital Controller (dual stage) with power cords for 1/4 - 1/3 hp 115v with 10 ft Ti submersible sensor |
DC115D-BS | Digital Controller (dual stage) with power cords for 1/4 - 1/3 hp 115v with 10 ft bare sensor |
DC230S | Digital Controller (single stage) with power cords for 3/4 - 1 1/2 hp 230v with 10 ft Ti submersible sensor |
DC230D | Digital Controller (dual stage) for 3/4 - 1 1/2 hp 230v with 10 ft Ti submersible sensor |
DC-DSHP-4-5-BS | Digital Controller (dual stage) for DSHP-4 & 5 heat pump with 10 ft bare sensor |
DC-DSHP-6 | Digital Controller (dual stage) for DSHP-6 heat pump with 10 ft Ti submersible sensor |
Specifications
Controls chilling or heating equipment
Push-button controls for easy programming of set points, differential, and heating/cooling mode
Keypad lockout to prevent tampering
Non-volatile memory retains control settings during power outages
Programmable in Fahrenheit or Celsius
Differential programmable to 1ºF
Titanium encapsulated sensor for maximum protection from water
Microprocessor-based operation for accurate temperature settings.
Includes power cord and remote sensor on 8ft cable
NEMA 4x rated water tight enclosure protects internal electrical
Rated for indoor/outdoor use
Easy plug in design (most models)
Product Literature
TR115SN and TR230SN Instructions
TR115DN Instructions
DC24S Instructions
DC24D Instructions
DC-115S, DC-115S-20, and DC-230S Instructions
DCW-115, DCW-220, DC-115S, and DC-230S Instructions
DC115D Instructions
DC-DSHP Instructions
TR115SN Specification Sheet
TR115DN Specification Sheet
TR230SN Specification Sheet
DCW-115 Specification Sheet
DC115-20 and DC230S Specification Sheet