Chillers

Cyclone Series

Sizing
Use the tables below to determine the appropriate Cyclone Chiller model for your application.
Please note that the tables make the following assumptions:
  • Calculations are based on a closed recirculating system with chiller running full time.
  • Does not take into account, multiple pumps, protein skimmers, high intensity lighting, or other such variables.

Cyclone Drop-in Chillers

Model No.

HP

Nominal BTUH

Volts/phase

Amps

Watts

Water flow (GPM)

Air output (CFM)

L (in.)

W (in.)

H (in.)

Coil Length (in.)

Coil Height (in.)

Shipping Weight (lbs.)

Shipping Dimensions (in.)

CY-3

1/4

3000

115

5.4

621

8 - 15

240

17.5

13.5

11.25

7.25

2.125

53

26 x 16 x 15

CY-4

1/3

4000

115

7.2

828

10 - 20

260

17.5

13.5

11.25

9

2.125

62

26 x 16 x 15

CY-5

1/2

6000

115

9.5

1092

12 - 25

350

17.5

15.25

13.125

9.125

3

110

33 x 26 x 24

CY-6

1/2

6000

230/1

4.8

1104

12 - 25

350

17.5

15.25

13.125

9.124

3

112

33 x 26 x 24

Specifications
Standard
  • Ideal for tropical aquariums and warm water exhibits, or research applications.
  • Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
  • Amount of refrigerant does not need to change since the water temperature is being maintained at a constant.
‘CWCT’ (Cold Water Cap Tube)
*Add “CWCT” (cold water cap tube) to the model # for desired water temps between 50-65F on available models.*
  • Allows for a lower, but more limited temperature range.
  • Ideal for bait fish holding, temperate fish exhibits, and hydroponics.
  • Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
  • Amount of refrigerant does not need to change since the water temperature is being maintained at a constant.
Product Literature

Cyclone Plus

Sizing
Use the table below for sizing info for the CY Plus.
Please note that the table makes the following assumptions:
  • Calculations are based on a closed recirculating system with the chiller running full time.
  • Does not take into account multiple pumps, protein skimmers, high-intensity lighting, or other such variables.

Specification

CY-Plus

Model no.

CYP007

Nominal capacity

1/2 HP+ / 7,000 BTU/H / 2.05 kW

Compressor

1/2 HP rotary

Refrigerant

R-454B (A2L), 10 oz charge

Electrical

115V / 1 Ph / 60 Hz

Compressor amps

5.9 RLA / 35 LRA

Fan amps

0.5 FLA

Power cord

6 ft, NEMA 5-15P plug

Air output

380 CFM

Condenser

Aluminum microchannel (MCHE)

Heat exchanger

Titanium drop-in coil, flexible hose

Coil size

9 1/8" L × 3 1/2" H

Hose length

72 in (6 ft)

Water flow across coil

Ensure minimum flow across the coil

Water level over coil

6" min. / 8" max.

Control

Digital with voltage protection, fan-failure alarm, and dirty-condenser alarm

Cabinet cover

304 stainless steel

Cabinet dimensions

14 3/4" W × 18 1/4" D × 14 1/2" H

Shipping dimensions

30 1/2" × 18 1/2" × 18 1/2"

Ambient air temperature

45°F – 100°F

Weight

57 lbs.

Specifications
“TXV” (Thermal Expansion Valve)
  • Provides both the lowest water temperature and the most broad temperature range.
  • Required for applications where the unit will need to maintain a very cold temperature.
  • Ideal for lobster tanks, cold water fish exhibits, or research applications.
  • The thermal expansion valve constantly regulates the amount of refrigerant going to the heat exchanger based on the desired water temperature.
Product Literature

Delta-Star Series Inline Air-Cooled Chillers

Sizing
The following table can be used to determine the appropriate Delta Star Chiller Model for your application.
The table displays the maximum water volume (Gallons) that can be maintained at a range of temperature differences below the ambient air temperature. Please note that the tables make the following assumptions, and that for more accurate sizing or complex systems you should contact Aqua Logic for assistance:
  • Calculations based on a closed recirculating system with chiller running full time.
  • Please consult Aqua Logic for proper sizing if using multiple pumps, protein skimmers, high intensity lighting, or other such variables.

Delta Star® Air-Cooled Chillers

MODEL

HP

BTUH REMOVAL CAPACITY

VOLTS/PHASE

AMPS

FLOW (GPM) MIN/MAX

IN/OUT FIPT (IN)

LENGTH (IN)

WIDTH (IN)

HEIGHT (IN)

SHIPPING WEIGHT (LBS)

DS-3

1/4

3,000

115

5.4

8/15

3/4"

22 1/2"

13 1/2"

11 1/4"

62 lbs.

DS-4

1/3

4,000

115

7.2

10/20

3/4"

22 1/2"

13 1/2"

11 1/4"

62 lbs.

DS-5

1/2

6,000

115

9.5

12/25

1-1/2"

24"

15 1/4"

13 1/8"

110 lbs.

DS-6

1/2

6,000

230

4.8

12/25

1-1/2"

24"

15 1/4"

13 1/8"

112 lbs.

DS-7

3/4

9,500

115

15.4

15/30

1-1/2"

25"

24"

14 3/4"

145 lbs.

DS-8

3/4

9,500

230

8.4

15/30

1-1/2"

25"

24"

14 3/4"

145 lbs.

DS-9

1

12,000

230

9

20/35

1-1/2"

26 1/2"

28"

17 3/4"

150 lbs.

DS-10

1 1/2

21,000

230

10.5

25/40

1-1/2"

26 1/4"

26"

17 1/2"

190 lbs.

Specifications
Standard
  • Ideal for tropical aquariums and warm water exhibits, or research applications.
  • Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
  • Amount of refrigerant does not need to change since the water temperature is being maintained at a constant.
 
‘CWCT’ (Cold Water Cap Tube)
*Add “CWCT” (cold water cap tube) to model # for desired water temps between 50-65F on available models.*
  • Allows for a lower, but more limited temperature range.
  • Ideal for bait fish holding, temperate fish exhibits, and hydroponics.
  • Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
  • The amount of refrigerant does not need to change since the water temperature is being maintained at a constant.
 
“TXV” (Thermal Expansion Valve)
*Add “TXV” to model # for lower desired water temps between 40-80F on available models.*
  • Provides both the lowest water temperature and the most broad temperature range.
  • Required for applications where the unit will need to maintain a very cold temperature.
  • Ideal for lobster tanks, cold water fish exhibits, or research applications.
  • The thermal expansion valve constantly regulates the amount of refrigerant going to the heat exchanger based on the desired water temperature.
Product Literature

Delta-Star Plus

Sizing

The following table can be used to determine the appropriate Delta Star Chiller Model for your application.

The table displays the maximum water volume (Gallons) that can be maintained at a range of temperature differences below the ambient air temperature. Please note that the tables make the following assumptions, and that for more accurate sizing or complex systems you should contact Aqua Logic for assistance:

  • Calculations based on a closed recirculating system with chiller running full time.
  • Please consult Aqua Logic for proper sizing if using multiple pumps, protein skimmers, high intensity lighting, or other such variables.

Specification

DS Plus

Model

DSP007

Nominal capacity

7,000 BTU/H

Compressor

1/2+ HP

Refrigerant

R-454B

Electrical

120V / 1 Phase

Power cord

6 ft, NEMA 5-15P plug

Fan air output

1,708 CFM

Evaporator

Titanium tube in PVC shell

Water connections

1" FPT inlet and outlet

Water flow

12 - 25 GPM

Water pressure drop

2 PSIG

Water temperature range

40°F – 80°F

Ambient air temperature

35°F – 100°F

Control

Digital, short-cycle protection

Cabinet

304 Stainless Steel with marine coating

Cabinet dimensions

14 3/4" W × 18 1/4" D × 14 1/2" H

Shipping dimensions

30 1/2" × 18 1/2" × 18 1/2"

Air clearance

12" minimum, inlet and outlet

Weight

58 lbs

Specifications
“TXV” (Thermal Expansion Valve)
  • Provides both the lowest water temperature and the most broad temperature range.
  • Required for applications where the unit will need to maintain a very cold temperature.
  • Ideal for lobster tanks, cold water fish exhibits, or research applications.
  • The thermal expansion valve constantly regulates the amount of refrigerant going to the heat exchanger based on the desired water temperature.
Product Literature

Delta-Star Series Inline Water-Cooled Chillers

Sizing
The following table can be used to determine the appropriate Delta Star Chiller Model for your application.
The table displays the maximum water volume (Gallons) that can be maintained at a range of temperature differences below the ambient air temperature. Please note that the tables make the following assumptions, and that for more accurate sizing or complex systems you should contact Aqua Logic for assistance:
  • Calculations based on a closed recirculating system with chiller running full time.
  • Please consult Aqua Logic for proper sizing if using multiple pumps, protein skimmers, high-intensity lighting, or other such variables.

Delta-Star in-line Water-Cooled Chillers

Model No.

Rev.

Refrigerant

Nominal BTUH

HP

Volts

Phase

Amps

Water flow (GPM)

Condenser water flow (GPM)

In/Out (FIPT in)

L (in.)


W (in.)


H (in.)


DS-3-WC

B

513a

3000

1/4

115

1

5.4

8 - 15

0.30

3/4

22.5

13.5

11.25

DS-4-WC

B

513a

4000

1/3

115

1

7.2

10 - 20

0.5

3/4

22.5

13.5

11.25

DS-5-WC

B

513a

6000

1/2

115

1

9.5

12 - 25

0.7

1 1/2

24

15.25

13.125

DS-6-WC

B

513a

6000

1/2

230

1

4.8

12 - 25

0.7

1 1/2

24

15.25

13.125

DS-7-WC

B

513a

9500

3/4

115

1

13

15 - 30

1

1 1/2

25

24

14.75

DS-8-WC

B

513a

9500

3/4

230

1

7

15 - 30

1

1 1/2

25

24

14.75

DS-9-WC

B

513a

12000

1

230

1

7.2

20 - 35

1.5

1 1/2

26.5

28

17.75

DS-10-WC

B

513a

15000

1 1/2

230

1

10.8

25 - 40

2

1 1/2

28.625

27.5

22.375

DS-10-WC

D

404a

22000

1 1/2

230

1

10.8

25 - 40

2

1 1/2

28.625

27.5

22.375

Specifications
Standard
  • Ideal for tropical aquariums and warm water exhibits, or research applications.
  • Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
  • Amount of refrigerant does not need to change since the water temperature is being maintained at a constant.
 
‘CWCT’ (Cold Water Cap Tube)
*Add “CWCT” (cold water cap tube) to model # for desired water temps between 50-65F on available models.*
  • Allows for a lower, but more limited temperature range.
  • Ideal for bait fish holding, temperate fish exhibits, and hydroponics.
  • Capillary tube size allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger.
  • The amount of refrigerant does not need to change since the water temperature is being maintained at a constant.
 
“TXV” (Thermal Expansion Valve)
*Add “TXV” to model # for lower desired water temps between 40-80F on available models.*
  • Provides both the lowest water temperature and the most broad temperature range.
  • Required for applications where the unit will need to maintain a very cold temperature.
  • Ideal for lobster tanks, cold water fish exhibits, or research applications.
  • The thermal expansion valve constantly regulates the amount of refrigerant going to the heat exchanger based on the desired water temperature.
Product Literature

Multi-Temp Series Air-Cooled Packaged and Split

Sizing
A number of factors influence the correct size of chiller required for your application. While standard BTU calculations can be applied, and our Multi-Temp Chiller Specifications can offer some guidelines, the parameters of your application will be the deciding factor in correct size selection. Contact us today for help with sizing the perfect unit for your needs.
For spatial planning you can refer to the dimensions of each unit on our specifications table and use the following diagram as a guide. Custom sizes available.

Multi-Temp Series Air-Cooled

Model No.

Nominal Tons

Nominal BTUH

Volts/phase

Amps RLA/LRA

Water flow (GPM)

Air Outlet (CFM)

H (In.)

L (in.)

W (In.)

Shipping Weight (lbs.)

MT-1

2

24000

208-240/1


11/63

20 - 40

1282

59

44

33

370

MT-3

3

36000

208-240/1

18/77

20 - 40

2615

63

44

33

396

MT-4

3

36000

208-240/3

10/71

20 - 40

2615

66

44

33

386

MT-4-460

3

36000

460/3

6/38

20 -40

2615

66

44

33

386

MT-5

4

48000

208-240/1

23/124

30 - 60

2615

59

51

38

474

MT-6

4

48000

208-240/3

15/83

30 - 60

2615

63

51

38

474

MT-6-460

4

48000

460/3

7/41

30 - 60

2615

63

51

38

474

MT-7

5

60000

208-240/1

27/153

30 - 60

2785

70

51

38

520

MT-8

5

60000

208-240/3

17/110

30 - 60

2785

70

51

38

528

MT-8-460

5

60000

460/3

8/52

30 - 60

2785

70

51

38

528

MT-9

7.5

90000

208-240/3

28/164

60 - 120

5100

68

51

42

670

MT-9-460

7.5

90000

460/3

15/100

60 - 120

5100

68

51

42

670

MT-10

10

120000

208-240/3

35/225

60 - 120

7500

68

61

46

815

MT-10-460

10

120000

460/3

19/114

60 - 120

7500

68

61

46

815

MT-12

12

150000

208-240/3

50/149

60 - 120

7800

74

61

46

965

MT-12-460

12

150000

460/3

27/75

60 - 120

7800

74

61

46

965

MT-15

15

180000

208-240/3

50/164

120 - 180

9750

78

111.5

53

1559

MT-15-460

15

180000

460/3

25/100

120 - 180

9750

78

111.5

53

1559

MT-20

20

240000

208-240/3

78/267

120 - 180

9750

91

111.5

53

1714

MT-20-460

20

240000

460/3

40/142

120 - 180

9750

91

111.5

53

1714

MT-25

25

300000

208-240/3

82/267

120 - 180

15500

75

122

53

2000

MT-20-460

25

300000

460/3

40/142

120 - 180

15500

75

122

53

2000

Specifications
  • Insulated Titanium Heat Exchanger
  • Dual-Stage Digital Temperature Controller in NEMA 4X enclosure
  • Built-in Safety Flow Switch
  • Temperature Range down to 40ºF
  • Includes stainless-steel stand
  • Fresh or Saltwater use
  • All units suitable for outdoor use
  • Made in the USA
Product Literature

Multi-Temp Series Water-Cooled Chillers

Sizing
A number of factors influence the correct size of chiller required for your application. While standard BTU calculations can be applied, and our Multi-Temp Chiller Specifications can offer some guidelines, the parameters of your application will be the deciding factor in correct size selection. Contact us today for help with sizing the perfect unit for your needs.
For spatial planning you can refer to the dimensions of each unit on our specifications table and use the following diagram as a guide. Custom sizes available.

Multi-Temp Series Water-Cooled Chillers

Model No.

Nominal Tons

Nominal BTUH

Volts/phase

Condenser Water flow (GPM)

Evaporator Water flow (GPM)

H (In.)

L (in.)

W (In.)

MT-1-WC

2

24000

208-240/1

2 - 4

20 - 40

34

39.5

20

MT-3-WC

3

36000

208-240/1

2 - 5

20 - 40

41

39.5

20

MT-4-WC

3

36000

208-240/3

2 - 5

20 - 40

41

39.5

20

MT-4-460-WC

3

36000

460/3

2 - 5

20 - 40

41

39.5

20

MT-5-WC

4

48000

208-240/1

3 - 7

30 - 60

49

39.5

20

MT-6-WC

4

48000

208-240/3

3 - 7

30 - 60

49

39.5

20

MT-6-460-WC

4

48000

460/3

3 - 7

30 - 60

49

39.5

20

MT-7-WC

5

60000

208-240/1

4 - 8

30 - 60

56.5

39.5

20

MT-8-WC

5

60000

208-240/3

4 - 8

30 - 60

56.5

39.5

20

MT-8-460-WC

5

60000

460/3

4 - 8

30 - 60

56.5

39.5

20

MT-9-WC

7.5

90000

208-240/3

9

60 - 120

63.38

39.5

20

MT-9-460-WC

7.5

90000

460/3

9

60 - 120

63.38

39.5

20

MT-10-WC

10

120000

208-240/3

9

60 - 120

63.38

39.5

20

MT-10-460-WC

10

120000

460/3

9

60 - 120

63.38

39.5

20

MT-15-WC

15

180000

208-240/3

13

120 - 180

72.25

55

20

MT-15-460-WC

15

180000

460/3

13

120 - 180

72.25

55

20

MT-20-WC

20

240000

208-240/3

17

120 - 180

81.5

55

20

MT-20-460-WC

20

240000

460/3

17

120 - 180

81.5

55

20

MT-20-WC

25

300000

208-240/3

17

120 - 180

81.5

55

20

MT-20-460-WC

25

300000

460/3

17

120 - 180

81.5

55

20

Specifications
  • Insulated Titanium Heat Exchanger
  • Inline Tube-in-Shell Evaporator
  • Water Control Valve for condenser
  • Remote Electronic Temperature Controller
  • Includes Stainless-Steel Frame
  • Fresh or Saltwater Use
  • Compact Design
  • Quiet Operation
  • Black ABS Cover
  • Various options for sizing and configuration
Product Literature

Pool & Spa Chiller Series

Sizing
Aqua Logic’s new PSC Pool & Spa Series are commercial water-cooled chillers built to work in enclosed equipment rooms, including the tight spaces beneath hydrotherapy pools. Because they reject heat into condenser water rather than the room air, they can run indoors without overheating the space.

MODEL NO.

45°F COIL NOMINAL TONS / BTUH / KW

VOLTS / PHASE

AMPS RLA / LRA

WATER FLOW RATE (GPM)

CONDENSER WATER FLOW RATE (GPM) (MIN/MAX)

H

L

W

HEAT EXCHANGER INLET/OUTLET SIZE

CONDENSER INTEL/OUTLET SIZE (FPT)

PSC024P2

2 / 24K / 7

208 - 240 / 1

17 / 96.7

20 / 40

2 / 4

38.75"

28"

26.5"

1-1/2"

1/2"

PSC024P3

2 / 24K / 7

208 - 240 / 3

12.8 / 95

20 / 40

2 / 4

38.75"

28"

26.5"

1-1/2"

1/2"

PSC036P2

3 / 36K / 10.5

208 - 240 / 1

21 / 115

20 / 40

2 / 5

38.75"

28"

26.5"

1-1/2"

1/2"

PSC036P3

3 / 36K / 10.5

208 - 240 / 3

14.7 / 115

20 / 40

2 / 5

38.75"

28"

26.5"

1-1/2"

1/2"

PSC048P2

4 / 48K / 14.1

208 - 240 / 1

26.3 / 150

20 / 40

3 / 7

38.75"

28"

26.5"

1-1/2"

1/2"

PSC048P3

4 / 48K / 14.1

208 - 240 / 3

17.6 / 120

30 / 60

3 / 7

38.75"

28"

26.5"

1-1/2"

1/2"

PSC060P2

5 / 60K / 17.6

208 - 240 / 1

26.9 / 145

30 / 60

4 / 8

48.25"

28"

26.5"

2"

3/4"

PSC060P3

5 / 60K / 17.6

208 - 240 / 3

23 / 160

30 / 60

4 / 8

48.25"

28"

26.5"

2"

3/4"

PSC090P3

7.5 / 90K / 26.4

208 - 240 / 3

27.9 / 250

30 / 60

5 / 9

48.25"

28"

26.5"

2"

3/4"

Specifications
    • Nine models cover 2 to 7.5 tons in 208–240V single- and three-phase, using A2L refrigerant R-454B and a titanium helical heat exchanger for fresh or salt water.
    • Compact 28″ × 26.5″ cabinets with lifting eyelets lower through tight equipment doors. 
    • Condenser water regulating valve shuts off condenser flow when the unit cycles off.
    • Protection includes electronic high/low pressure cutouts, a high condensing temperature alarm, an integrated flow switch, voltage protection, and refrigerant leak detection.
    • Made in the United States in Monroe, N.C.
Product Literature
  • Pool & Spa Chiller Series Instructions
  • Pool & Spa Chiller Series Specification Sheet

Heat Pumps

Delta-Star Series Air-Cooled Heat Pumps

Sizing
The following table can be used to determine the appropriate Delta Star Heat Pump Model for your application.
The table displays the maximum water volume (Gallons) that can be maintained at a range of temperature differences below the ambient air temperature. Please note that the tables make the following assumptions, and that for more accurate sizing or complex systems you should contact Aqua Logic for assistance:
  • Calculations based on a closed recirculating system with heat pump running full time.
  • Please consult Aqua Logic for proper sizing if using multiple pumps, protein skimmers, high-intensity lighting, or other such variables.

Delta-Star Air-Cooled Heat Pump

MODEL
NO.

HP

NOMINAL
BTUH

R134A
REFRIGERANT
CHARGE
(OZ)

VOLTS /
PHASE

AMPS.

WATTS

WATER
FLOW
RATE
(GPM)

AIR
OUTLET
(CFM)

L

W

H

WO

WC
WATER
IN / OUT
(FPT)

DSHP-4

1/3

4,000

8.5

115

7.2

828

10-20

260

22 1/2"

13 5/8"

14"

7 1/4"

3/4"

DSHP-5

1/2

6,000

10

115

9.5

1092

12-25

350

24"

15 3/8"

15 1/2"

9 1/4"

1 1/2"

DSHP-6

1/2

6,000

10

230 / 1

4.8

1104

12-25

350

24"

15 3/8"

15 1/2"

9 1/4"

1 1/2"

DSHP-7

3/4

9500

R134A / 38

115

15.4

70

19.2

590

23 3/4"

23 3/4"

14 7/8"

9 1/4"

1 1/2"

DSHP-8

3/4

9500

R134A / 48

230 / 1

7

1610

15 - 30

590

23 3/4"

23 3/4"

14 7/8"

9 1/4"

1 1/2"

DSHP-9

1

12,000

R134A / 56

230 / 1

7.2

1656

20 - 35

610

26 1/4"

27 1/2"

17 5/8"

9 1/4"

1 1/2"

DSHP-10

1 1/2

21,000

R404A / 72

230 / 1

10.5

2415

25 - 40

772

26 1/4"

26 1/4"

17 5/8"

12"

1 1/2"

Specifications
Features:
  • Reversible refrigeration cycle provides both cooling and heating in one package
  • In-line PVC tube-in-shell with titanium heat exchanger coil(s)
  • Dual-stage electronic temperature controller, NEMA 4X
  • Temperature range of 40°F – 85°F water
  • Optional water flow switch
System Requirements:
  • An external pump is required to move water through the heat exchanger. Pumps are not included.
  • Heat pumps must not be placed in a confined space, as restricted airflow will damage the unit.
  • Designed for indoor use.
Product Literature

Titan Series Air-Cooled Heat Pump

Sizing
A number of factors influence the correct size of chiller required for your application. While standard BTU calculations can be applied, and our Titan Heat Pump Specifications can offer some guidelines, the parameters of your application will be the deciding factor in correct size selection. Contact us today for help with sizing the perfect unit for your needs.
For spatial planning you can refer to the dimensions of each unit on our specifications table and use the following diagram as a guide. Custom sizes available.

Titan Air-Cooled Heat Pumps

Model No.

Nominal Tons

Nominal BTUH

Volts/phase

Amps RLA/LRA

Water flow (GPM)

Air Outlet (CFM)

H (In.)

L (in.)

W (In.)

HP-1

1.5

18000

208-240/1

6/38

20 - 40

1550

59

44

33

HP-2

2

24000

208-240/1

8.7/57

20 - 40

1550

63

44

33

HP-3

3

36000

208-240/1

14/91

20 - 40

2175

63

51

38

HP-33

3

36000

208-240/3

10.9/74

20 - 40

2175

63

51

38


HP-33-460

3

36000

460/3

5.5/38

20 - 40

2175

63

51

38


HP-4

4

48000

208-240/1

18.6/94

30 - 60

2500

67

51

38


HP-43

4

48000

208-240/3

13.7/101

30 - 60

2500

67

51

38


HP-43-460

4

48000

460/3

7/41

30 - 60

2500

67

51

38


HP-5

5

60000

208-240/1

25/148

30 - 60

3700

75

51

38


HP-53

5

60000

208-240/3

18.6/94

30 - 60

3700

75

51

38


HP-5-460

5

60000

460/3

9/71

30 - 60

3700

75

51

38


HP-6

7.5

90000

208-240/3

29/172

60 - 120

5200

65

51

42

HP-6-460

7.5

90000

460/3

15/94

60 - 120

5200

65

51

42

HP-7

10

120000

208-240/3

40/278

60 - 120

5200

74

61

46

HP-7-460

10

120000

460/3

15/90

60 - 120

5200

74

61

46

HP-15

15

180000

208-240/3

50/164

120 - 180

9750

78

111.5

53

HP-15-460

15

180000

460/3

25/100

120 - 180

9750

78

111.5

53


HP-20

20

240000

208-240/3

78/267

120 - 180

9750

91

111.5

53


HP-20-460

20

240000

460/3

40/142

120 - 180

9750

91

111.5

53


Specifications
  • 1.5 HP – 20 HP
  • Heat or Chill with one unit
  • Insulated Titanium Heat Exchanger
  • Dual-Stage Digital Temperature Controller in NEMA 4X enclosure
  • Built-in Safety Flow Switch
  • Includes stainless-steel stand
  • Fresh or Saltwater use
  • All units suitable for outdoor use
Product Literature

Titan Series Water-Cooled Heat Pump

Sizing
A number of factors influence the correct size of chiller required for your application. While standard BTU calculations can be applied, and our Titan Heat Pump Specifications can offer some guidelines, the parameters of your application will be the deciding factor in correct size selection. Contact us today for help with sizing the perfect unit for your needs.
For spatial planning you can refer to the dimensions of each unit on our specifications table and use the following diagram as a guide. Custom sizes available.
Specifications
  • 2 HP – 25 HP
  • Heat or Chill with one unit
  • Insulated Titanium Heat Exchanger
  • Inline Tube-in-Shell Evaporator
  • Water Control Valve for condenser
  • Remote Electronic Temperature Controller
  • Includes Stainless Steel Frame
  • Fresh or Saltwater Use
  • Compact Design
  • Quiet Operation
  • Black ABS Cover
  • Various options for size and configuration
Product Literature

Electric Heaters

Cygnet Series Mini Electric Heaters

Sizing
System Requirements:
  • Requires an external pump to move water through the heater
  • Observe the minimum and maximum flow rates to avoid damage to the heater
  • Pre-filtration and suitable water quality are required to prevent buildup
  • Maintenance schedule will vary by application, periodic cleaning is the only required maintenance

Cygnet Mini Electric Heaters

Part No.

Heating Capacity KW

Volts/Phase

Load Amps

Minimum Water Flow (GPM)

In/Out (NPS ABS union)

AL-KC-0.5-115T

0.5

115/1

4.5

5

1 1/2"

AL-KC-0.5-115T

1

115/1

8.5

5

1 1/2"

AL-KC-0.5-115T

1.5

115/1

12.75

5

1 1/2"

Specifications
  • 3 models in a very compact package from 0.5 kW → 1.5 kW
  • Easy installation, fully equipped and pre-wired
  • Reliable flow switch for safe operation
  • Analogue control thermostat with tight differential
  • Titanium flow tube and titanium heating element
  • Saltwater Compatible
Product Literature

EVO Series Electric Heaters

Sizing
System Requirements:
  • Requires an external pump to move water through the heater
  • Observe the minimum and maximum flow rates to avoid damage to the heater
  • Pre-filtration and suitable water quality are required to prevent buildup
  • Maintenance schedule will vary by application, periodic cleaning is the only required maintenance

EVO Series Electric Heaters

Part No.

Heating Capacity KW

Volts/phase

Load Amps

Minimum Water flow (GPM)

In/Out (NPS ABS union)

HSS-1.5-115

1.5

115 / 1

13

10

1.5"

HSS-2-115

2

115 / 1

17.4

10

1.5"

HSS-2-220

2

220 - 230 / 1

9

10

1.5"

HSS-3-220

3

220 - 230 / 1

13.6

10

1.5"

HTI-1.5-115

1.5

115 / 1

13

10

1.5"

HTI-2-115

2

115 / 1

17.4

10

1.5"

HTI-2-220

2

220 - 230 / 1

9

10

1.5"

HTI-3-220

3

220 - 230 / 1

13.6

10

1.5"

HTI-4-220

4

220 - 230 / 1

18

10

1.5"

Specifications
  • 5 models in a compact package from 1.5 kW → 4 kW
  • 115V and 220V options
  • Reliable flow switch for safe operation
  • Digital control thermostat with tight differential
  • Saltwater compatible
  • Titanium flow tube and coiled titanium heating element
  • Stay-clean vortex inducing flow over titanium heating element
Product Literature

Optima Compact Plus Series Electric Heaters

Sizing
System Requirements:
  • Requires an external pump to move water through the heater
  • Observe the minimum and maximum flow rates to avoid damage to the heater
  • Pre-filtration and suitable water quality are required to prevent buildup
  • Maintenance schedule will vary by application, periodic cleaning is the only required maintenance

Optima Compact Plus Electric Heaters

Part No.

Heating Capacity KW

Volts/phase

Load Amps

Minimum Water flow (GPM)

In/Out (NPS ABS union)

HTIO-6-220

6

220 - 230 / 1

28

10

1.5"

HTIO-8-220

8

220 - 230 / 1

37

10

1.5"

HTIO-12-220

12

220 - 230 / 1

55

25

1.5"

HTIO-15-220

15

220 - 230 / 1

69

25

1.5"

HTIO-18-220

18

220 - 230 / 1

82

25

1.5"

HTIO-6-220-3

6

220 - 230 / 3

16

10

1.5"

HTIO-8-220-3

8

220 - 230 / 3

22

10

1.5"

HTIO-12-220-3

12

220 - 230 / 3

32

25

1.5"

HTIO-15-220-3

15

220 - 230 / 3

40

25

1.5"

HTIO-18-220-3

18

220 - 230 / 3

48

25

1.5"

HTIO-9-460-3

9

460 - 480 / 3

11 - 11.5

10

1.5"

HTIO-12-460-3

12

460 - 480 / 3

14.5 - 15

10

1.5"

HTIO-17-460-3

17.5

460 - 480 / 3

21 - 22

25

1.5"

HTIO-19-460-3

19.5

460 - 480 / 3

23.5 - 24.5

25

1.5"

Specifications
  • 14 models in a compact package from 6 kW → 18kW
  • 220–230 V single–phase and three-phase, plus 460V three-phase options
  • Reliable flow switch for safe operation
  • Touch screen digital control thermostat with tight differential
  • Stay-clean vortex inducing flow over titanium heating element
  • Saltwater Compatible
Product Literature

Titan Optima Series Electric Heaters

Sizing
System Requirements:
  • Requires an external pump to move water through the heater
  • Observe the minimum and maximum flow rates to avoid damage to the heater
  • Pre-filtration and suitable water quality are required to prevent buildup
  • Maintenance schedule will vary by application, periodic cleaning is the only required maintenance
Specifications
  • Stay-clean vortex inducing Titanium heating elements
  • Titanium flow tube; corrosion resistant even with seawater
  • External reversible flow; allows water flow from either direction
  • Floor or wall mountable (bracket supplied)
  • Inlet manifold has been designed to eliminate the risk of air locking
  • High Limit Thermostat Internal Fail Safe, manual reset thermostat, for positive safety
  • Touch Screen Digital thermostat with 33ºF differential
  • Little to no servicing required; Varies with use
  • Silent Operation
  • Saltwater compatible
  • Robust and durable
  • 1 year limited warranty
  • 1½” female thread with supplied:1½” ABS unions for rigid pipe and 1½” x 1¼” hose barb fittings for flexible pipe
  • Status indicator panel
  • Dual cascade-wired Schneider contactors
Product Literature

Gas Heaters

ALB Series Gas Heaters

Sizing
For large applications where an electric heater is not practical, turn to our range of gas heaters. Aqua Logic offers our ALB series of gas heaters in both propane and natural gas for indoor or outdoor use. A wide range of capacities is available, with inputs from 84K → 2 million BTUH. The package includes a titanium heat exchanger to ensure you won’t have corrosion or toxic metallic elements leaching into your water.
Specifications
  • 84K → 2 million+ BTUH
  • Titanium tube heat exchanger for fresh or saltwater use
  • Available for use with natural gas or propane
  • Indoor and outdoor applications
  • Digital LED process water temperature controller
  • Pre-plumbed and ready to install
  • Raypac Commercial Boiler with built-in safety controls
  • Standard temperature range → 65° – 85°F
Product Literature

UV Sterilizers

Comet Series UV Sterilizers

Sizing
A powerful and economical choice for smaller water volumes with low flow rates. Available in four sizes, the Comet can handle up to 165 GPM and can be mounted horizontally or vertically.

Comet UV Sterilizer

Optional Fiberglass Mounting Bracket Part No.

Model No. 

 Lamp/Watts

 Volts/phase

Amps/watts

 Water inlet/Outlet

  Maximum Water Flow Rate (GPM) at UV Intensity µWsec/cm2 @90% transmissibility 85% at end of lamp life

30k

45k

60k

90k

120k

ALSLT-95-4

1/95

115

.9/104

1 1/2" FPT

25

17

13

8

6

UV-MB-4

ALSLT-95-6

1/95

115

.9/104

1 1/2" Union

35

23

18

12

9

UV-MB-6

ALSLT-190-6

2/190

115

1.8/207

2" Union

70

46

36

24

18

UV-MB-6

ALSLT-190-8

2/190

115

1.8/207

3" Union

110

73

55

36

28

UV-MB-8

Specifications
  • 5 models in a compact package, 190 – 760 watts
  • Flow rates up to 300 GPM
  • Indoor or outdoor use
Product Literature

Corona Series UV Sterilizers

Sizing

Corona UV Sterilizers

 Model No.

 Model No. Horizonal

 Lamp/Watts

 Volts/phase

 Amps/watts

Water inlet/Outlet

  Maximum Water Flow Rate (GPM) at UV Intensity µWsec/cm2 @90% transmissibility 85% at end of lamp life 

30k

45k

60k

90k

120k

ALSV-2

ALSH-2DX

2/190

115

1.8/207

2" FPT

50

33

25

16

13

ALSV-3

ALSH-3DX

3/285

115

2.5/287

3" Union

75

50

37

25

18

ALSV-4

ALSH-4DX

4/380

115

3/345

3" Union

100

67

50

37

25

ALSV-5

ALSH-5DX

5/475

115

4.5/517

4" Union

150

100

75

50

33

ALSV-6

ALSH-6DX

6/570

115

5.4/621

6" Union

200

133

100

75

50

ALSV-8

ALSH-8DX

8/760

115

7.2/828

6" Union

200

133

100

75

50

Specifications
  • 6 models in a compact package spanning 190 – 760 watts
  • Convenient vertical and horizontal models to accommodate tight spaces
  • Flow rates up to 800 GPM
  • Indoor or outdoor use (if protected from the elements)
  • 220 – 230V in single-phase and three-phase, plus 460V three-phase options
Product Literature

Super Nova Series UV Sterilizers

Sizing

Super Nova UV Sterilizers

Model No.

Lamp/Watts

Volts/phase

Amps/watts

 Chamber Diameter

Water inlet/Outlet

Maximum Water Flow Rate (GPM) at UV Intensity µWsec/cm2 @90% transmissibility 85% at end of lamp life

30k

45k

60k

90k

120k

ALS-7608.12

8/760

115

6/690

12"

6" flange

408

271

204

135

102

ALS-95010.12

10/950

115

7.5/863

12"

6" flange

500

333

250

166

125

ALS-114012.12

12/1140

115

9/1035

12"

6" flange

560

372

280

187

140

ALS-114012.16

12/1140

115

9.1035

16"

6" flange

693

460

346

231

173

ALS-133014.16

14/1330

220

10.5/1150

16"

8" flange

780

519

390

260

195

ALS-152016.16

16/1520

220

12/1380

16"

8" flange

876

583

438

292

219

Specifications
  • 5 models in a very compact package
  • Low-pressure, high-output lamps ranging from  95 – 190 watts
  • Low operating cost
  • Easy installation and maintenance
  • Fresh or saltwater
Product Literature

Replacement Parts

Digital Temperature Controllers

Sizing
Aqua Logic’s digital temperature controllers can be used in a variety of applications where a device needs to be turned on / off based on temperature rise or fall.

TR115SN

Digital Controller (single stage) with power cords for 1/4 - 1/2 hp chillers 115v with 7 ft Ti submersible sensor

TR115DN

Digital Controller (dual stage) with power cords for 1/4 - 1/3 hp chillers & up to 500 watt heater 115v with 7 ft Ti submersible sensor

TR230SN

Digital Controller (single stage) with power cords for 1/2 hp chiller 230v with 7 ft Ti submersible sensor

CONT-RAW-TRSN

Digital Controller (single stage) Unwired for 1/4 - 1/2 hp 115v with 7 ft bare sensor

CONT-RAW-TRDN

Digital Controller (dual stage) Unwired for 2015 and older heat pumps 115 / 230V with 7 ft bare sensor

DCS-BS

Digital Controller (single stage) for HXW, 115/230V Unwired with 10 ft bare sensor

DC24S

Digital Controller (single stage) for MT chillers, HX-DX, 24 VAC Unwired with 10 ft bare sensor

DC24D

Digital Controller (dual stage) for HP heat pump, HX-DXD, 24 VAC

DCW-115

Digital Controller 115V Input-24V Output, Temperature controller for water to water heat exchanger packages, HX-4W thru HX-60W.

DC115S

Digital Controller (single stage) for 1/4 - 1/2 hp 115v with 10 ft Ti submersible sensor

DC115S-BS

Digital Controller (single stage) with power cords for 1/4 - 1/2 hp 115v with 10 ft bare sensor

DC115S-20

Digital Controller (single stage) with power cords for 3/4 hp 115v with 10 ft Ti submersible sensor

DC115S-20-BS

Digital Controller (single stage) with power cords for 3/4 hp 115v with 10 ft bare sensor

DC115D

Digital Controller (dual stage) with power cords for 1/4 - 1/3 hp 115v with 10 ft Ti submersible sensor

DC115D-BS

Digital Controller (dual stage) with power cords for 1/4 - 1/3 hp 115v with 10 ft bare sensor

DC230S

Digital Controller (single stage) with power cords for 3/4 - 1 1/2 hp 230v with 10 ft Ti submersible sensor

DC230D

Digital Controller (dual stage) for 3/4 - 1 1/2 hp 230v with 10 ft Ti submersible sensor

DC-DSHP-4-5-BS

Digital Controller (dual stage) for DSHP-4 & 5 heat pump with 10 ft bare sensor

DC-DSHP-6

Digital Controller (dual stage) for DSHP-6 heat pump with 10 ft Ti submersible sensor

Specifications
  • Controls chilling or heating equipment
  • Push-button controls for easy programming of set points, differential, and heating/cooling mode
  • Keypad lockout to prevent tampering
  • Non-volatile memory retains control settings during power outages
  • Programmable in Fahrenheit or Celsius
  • Differential programmable to 1ºF
  • Titanium encapsulated sensor for maximum protection from water
  • Microprocessor-based operation for accurate temperature settings.
  • Includes power cord and remote sensor on 8ft cable
  • NEMA 4x rated water tight enclosure protects internal electrical
  • Rated for indoor/outdoor use
  • Easy plug in design (most models)
Product Literature